background image

 

 c)

 REFRIGERATION  

 

The Refrigeration Phase (Diagram 2) 

Following carbonation, the water travels through the cooling coils immersed inside a 

thermally insulated plastic water chiller bucket containing the ice bank. The refrigeration 

system is controlled by a thermostat device that regulates the temperature of the water inside 

the chiller bucket which then controls the start and stop of the compressor. The temperature 

sensor is connected with the thermostat and it is immersed in the water inside the chiller 

bucket. The thermostat can be manually adjusted depending on the desired temperature of 

the water. 

 

3.4  Technical Information 

 

The 

Natura

®

 Water Dispenser is made up of 

two separate units 

enclosed in a stainless 

steel sheet metal casing: 

 

o

  One is the

 Water Filtration Set 

that contains two stages of filtration. The first stage is 

for filtering sediments and other particles present in the water. The second stage is the 

carbon filter which eliminates chlorine taste and odor from the water.

 

 

o

  The second unit is the 

Refrigeration & Carbonation Unit

 that is made up of a 

compressor, a fan, agitator, water chiller bucket (or ice bank) and stainless steel coils 

for cooling the drinking water. It also includes the section for making sparkling water: 

the carbonator tank, high pressure water pump and motor.

 

 

The 

supply

 

of treated water

 is dispensed by three faucets with levers situated in the upper 

front area of the machine. (1) The green handle or button is for treated, cold sparkling 

(carbonated water); (2) the blue handle or button is for treated cool temperature water; and 

(3) the white handle or button dispenses treated room temperature water.  

 

The unit comes complete with stainless steel spillage collection tray or drip tray. 

 
 

 

Содержание NWSB SERIES 3

Страница 1: ...1 INSTALLATION AND MAINTENANCE INSTRUCTION MANUAL FOR NATURA MODEL NWSB SERIES 3 WATER DISPENSER NATURA Engineering Technical Service Dept 222 East Campus View Blvd Columbus Ohio 43235 U S A...

Страница 2: ...e This Section of Manual Reserved for Qualified Service Technician or Personnel Only 6 Installation 6 1 Directions for Unpacking 6 2 Directions for proper assembly 6 2 1 Installing the Faucets 6 3 Dir...

Страница 3: ...KLING ROOM TEMPERATURE STILL WATER REFRIGERATION UNIT DRIP TRAY FILTER SET CO2 PRESSURE REGULATOR TUBING WHAT S INCLUDED FAUCETS NOT ASSEMBLED TO UNIT FOR SHIPMENT 3 8 OD 1 4 OD WATER VALVE AND PRESSU...

Страница 4: ...CO2 canister valve is completely open o Use only super dry CO2 UN1013 gas for drinking water o Adjust the CO2 regulator pressure to 60 65 psig o When cleaning the unit do not use corrosive acidic pro...

Страница 5: ...or Vendor of the Unit or you may contact Natura Water Inc 222 East Campus View Blvd Columbus Ohio 43235 3 3 Description of Functions The Natura water dispenser units are made for a WATER TREATMENT Th...

Страница 6: ...r Filtration Set that contains two stages of filtration The first stage is for filtering sediments and other particles present in the water The second stage is the carbon filter which eliminates chlor...

Страница 7: ...D PLASTIC BUCKET EVAPORATOR COIL DIAGRAM 2 EXAMPLE OF REFRIGERATION SYSTEM Nano Ceram Filtration Sediment Filter 1 Carbon Filter 2 REFRIGERATION CARBONATION UNIT UNIT FILTRATION BOX WATER CHILLER COIL...

Страница 8: ...IT DIAGRAM 5 THERMOSTAT DIAGRAM 6 CO2 CANISTER REGULATOR LOCATED ON THE BACK 1 Carbonator Tank 2 Level Float 3 Switch Box 4 Carbonator Pump and Motor 5 CO2 and H2O Check Valves 6 CO2 Pressure Regulato...

Страница 9: ...AIR FILTER STEP 1 STEP 2 STEP 3 1 REMOVE TWO SCREWS 2 LIFT FRONT EDGE OF TOP 1 INCH 3 PUSH THE TOP BACK AND REMOVE 4 LIFT AND REMOVE THE AIR FILTER 5 REPLACE AIR FILTER AND REVERSE THE STEPS TO REPLA...

Страница 10: ...easonable and the manufacturer will not respond to subsequent damages that may arise 4 TRANSPORTATION A thin plastic protective film covers the external stainless steel casing of the water purifier un...

Страница 11: ...eplace the air filter every 12 months or when there is a noticeable reduction in cold water production o Check the heat exchange water tub monthly Add distilled or de ionized water until the water lev...

Страница 12: ...ng top pad o Locate the white blue and green bands found on the faucet levers These indicate the type of water each faucet dispenses and the location on the front panel o Starting on the left install...

Страница 13: ...t o Maintain at least 3 inches on sides for proper ventilation o Allow 14 inch minimum above the unit for removing the top to perform routine maintenance o Position the filter box within 6 feet of the...

Страница 14: ...the regulator o Insert the other end of the tube assembly into the inlet quick connect fitting on the left side of the filtration box ATTENTION IT IS IMPORTANT TO MAKE PROPER CONNECTION TO THE QUICK C...

Страница 15: ...ER CARTRIDGES The sediment filter white is located on the left The carbon filter black with netting is located on the right Make sure that the cartridge slips down over the stand pipe in the bottom of...

Страница 16: ...ulling the tube out NOTE Systems are shipped with a plug in each external fitting Remove a plug in the same manner as a tube Push tube through Collet into Body Tube must seat firmly at bottom of fitti...

Страница 17: ...urn on the power switch of the unit The switch will LIGHT to indicate that power is ON o Set the cold control to full cold full clockwise rotation of the dial or screw o Before using the machine allow...

Страница 18: ...That is a unit that is used constantly should be cleaned more frequently than a unit that is used on infrequently 7 3 Replacing the Disposable Filter Cartridges o Turn off the main water supply line a...

Страница 19: ...ower to the unit and make any necessary changes and calibration 7 4 Replacing the Air Filter DIAGRAM 7 o Turn off the power switch and Disconnect the electric power cord from the outlet o Remove the t...

Страница 20: ...pped the agitator is still working Thermostat was set too warm Water Insufficient quantity in the chiller bucket Check the setting of the thermostat Refill the tub with distilled water The refrigerati...

Страница 21: ...r in the carbonator tank Calibrate the pressure regulator so that outgoing CO2 pressure is between 90 to 100 psi Replace the CO2 tank Check that the motor and pump are working well Let the air out by...

Страница 22: ...knob counter clockwise Water comes out very slowly Tubes are kinked Water shut off valve closed or set to minimum Tubes are clogged Sediment or Carbon filter is blocked or excessively dirty Water pre...

Страница 23: ...ounces R 134a Input Voltage 115 VAC 60 HZ SINGLE PHASE Amperage 10 AMPS FLA Minimum Ambient Temperature 40 F 4 5 C Maximum Ambient Temperature 104 F 43 C Inlet Water Pressure 30 PSI 120 PSI SINGLE PHA...