22
Water does not come out of the
faucet.
- The water is frozen around the
coils.
- Water tubes are clogged.
- Water tubes are kinked.
- Polycarbonate adaptor to the
faucet is seized.
- The knob regulating the
adaptor is closed.
-If ice has formed in the chiller
bucket, lower the thermostat to 3.
- Wash tubes that supply the
drinking water.
- Shut water off, remove the
faucet, remove the adaptor and
wash everything.
- Turn the knob counter clockwise.
Water comes out very slowly.
- Tubes are kinked.
- Water shut-off valve closed or
set to minimum.
- Tubes are clogged.
- Sediment or Carbon filter is
blocked or excessively dirty.
- Water pressure is too low.
- Water pressure valve
malfunction.
- Check and clean the tubes.
- Open completely the water
supply line shut-off valve.
- Replace the filters (see section
7.3),
- Check the water pressure to the
unit (pressure should be approx.
50 psi).
- Check the main water supply
line.
13.