background image

 

10 

3.5      Usage Limits 

 

o

  Connect  to  a  POTABLE  WATER  supply  only.  If  the  water  has  high 

turbidity or sediment, then install an additional pre-filter prior to the main 

filtration box. 

 

o

  The unit cannot be used to treat sewage, salt water, chemically 

conditioned water, or water with physical or bacterial properties that will 

keep the water from being treated effectively. 

 

o

  The water dispenser is not designed to operate in excess humidity, 

outdoor environments, or in excessive heat environments. Therefore, it is 

advised not install or use the unit in the aforementioned environments. 

 

o

  On a daily basis, it is important to remove three liters of water from the 

tap prior to drinking the dispense water. 

 

3.6       Proper Use of Machine 

 

Use the water purifiers as described in this manual to properly treat 

drinking water. 

 

3.7       Improper Use of Machine 

 

Anything not mentioned in point 3.6.  Any other use is to be considered 

unreasonable and the manufacturer will not respond to subsequent 

damages that may arise. 

 

4. 

TRANSPORTATION: 

 

A thin plastic protective film covers the external stainless steel casing of the water purifier 

units and the filtration box. This protective cover must not be removed until the unit is ready 

for installation to avoid any scratches or stain on the surface of the casing. When shipping, it 

is important to apply labels with ‘FRAGILE’ warnings on the outsides of the box.  

 

4.1   Transportation and Movement 

The Water purifier must always be in a vertical (“   Up”) position when 

being transported or moved and handled with special attention due to its 

‘Delicate’ nature.  

 

4.2

     

Storage of the Unit

 

The unit should not be exposed to a very high humidity condition and 

should only be stored in a dry, cool place. Do not stack the units more 

than two high without any proper support or protection on the top 

surface. 

 

4.3      Unpacking 

Cut the banding with box cutter then remove the top and outer sleeve. 

Lift the unit off the bottom pad. Peel the protective film off the stainless 

steel panels when the unit is in its final location. 

 

 

Содержание NWSB SERIES 3

Страница 1: ...1 INSTALLATION AND MAINTENANCE INSTRUCTION MANUAL FOR NATURA MODEL NWSB SERIES 3 WATER DISPENSER NATURA Engineering Technical Service Dept 222 East Campus View Blvd Columbus Ohio 43235 U S A...

Страница 2: ...e This Section of Manual Reserved for Qualified Service Technician or Personnel Only 6 Installation 6 1 Directions for Unpacking 6 2 Directions for proper assembly 6 2 1 Installing the Faucets 6 3 Dir...

Страница 3: ...KLING ROOM TEMPERATURE STILL WATER REFRIGERATION UNIT DRIP TRAY FILTER SET CO2 PRESSURE REGULATOR TUBING WHAT S INCLUDED FAUCETS NOT ASSEMBLED TO UNIT FOR SHIPMENT 3 8 OD 1 4 OD WATER VALVE AND PRESSU...

Страница 4: ...CO2 canister valve is completely open o Use only super dry CO2 UN1013 gas for drinking water o Adjust the CO2 regulator pressure to 60 65 psig o When cleaning the unit do not use corrosive acidic pro...

Страница 5: ...or Vendor of the Unit or you may contact Natura Water Inc 222 East Campus View Blvd Columbus Ohio 43235 3 3 Description of Functions The Natura water dispenser units are made for a WATER TREATMENT Th...

Страница 6: ...r Filtration Set that contains two stages of filtration The first stage is for filtering sediments and other particles present in the water The second stage is the carbon filter which eliminates chlor...

Страница 7: ...D PLASTIC BUCKET EVAPORATOR COIL DIAGRAM 2 EXAMPLE OF REFRIGERATION SYSTEM Nano Ceram Filtration Sediment Filter 1 Carbon Filter 2 REFRIGERATION CARBONATION UNIT UNIT FILTRATION BOX WATER CHILLER COIL...

Страница 8: ...IT DIAGRAM 5 THERMOSTAT DIAGRAM 6 CO2 CANISTER REGULATOR LOCATED ON THE BACK 1 Carbonator Tank 2 Level Float 3 Switch Box 4 Carbonator Pump and Motor 5 CO2 and H2O Check Valves 6 CO2 Pressure Regulato...

Страница 9: ...AIR FILTER STEP 1 STEP 2 STEP 3 1 REMOVE TWO SCREWS 2 LIFT FRONT EDGE OF TOP 1 INCH 3 PUSH THE TOP BACK AND REMOVE 4 LIFT AND REMOVE THE AIR FILTER 5 REPLACE AIR FILTER AND REVERSE THE STEPS TO REPLA...

Страница 10: ...easonable and the manufacturer will not respond to subsequent damages that may arise 4 TRANSPORTATION A thin plastic protective film covers the external stainless steel casing of the water purifier un...

Страница 11: ...eplace the air filter every 12 months or when there is a noticeable reduction in cold water production o Check the heat exchange water tub monthly Add distilled or de ionized water until the water lev...

Страница 12: ...ng top pad o Locate the white blue and green bands found on the faucet levers These indicate the type of water each faucet dispenses and the location on the front panel o Starting on the left install...

Страница 13: ...t o Maintain at least 3 inches on sides for proper ventilation o Allow 14 inch minimum above the unit for removing the top to perform routine maintenance o Position the filter box within 6 feet of the...

Страница 14: ...the regulator o Insert the other end of the tube assembly into the inlet quick connect fitting on the left side of the filtration box ATTENTION IT IS IMPORTANT TO MAKE PROPER CONNECTION TO THE QUICK C...

Страница 15: ...ER CARTRIDGES The sediment filter white is located on the left The carbon filter black with netting is located on the right Make sure that the cartridge slips down over the stand pipe in the bottom of...

Страница 16: ...ulling the tube out NOTE Systems are shipped with a plug in each external fitting Remove a plug in the same manner as a tube Push tube through Collet into Body Tube must seat firmly at bottom of fitti...

Страница 17: ...urn on the power switch of the unit The switch will LIGHT to indicate that power is ON o Set the cold control to full cold full clockwise rotation of the dial or screw o Before using the machine allow...

Страница 18: ...That is a unit that is used constantly should be cleaned more frequently than a unit that is used on infrequently 7 3 Replacing the Disposable Filter Cartridges o Turn off the main water supply line a...

Страница 19: ...ower to the unit and make any necessary changes and calibration 7 4 Replacing the Air Filter DIAGRAM 7 o Turn off the power switch and Disconnect the electric power cord from the outlet o Remove the t...

Страница 20: ...pped the agitator is still working Thermostat was set too warm Water Insufficient quantity in the chiller bucket Check the setting of the thermostat Refill the tub with distilled water The refrigerati...

Страница 21: ...r in the carbonator tank Calibrate the pressure regulator so that outgoing CO2 pressure is between 90 to 100 psi Replace the CO2 tank Check that the motor and pump are working well Let the air out by...

Страница 22: ...knob counter clockwise Water comes out very slowly Tubes are kinked Water shut off valve closed or set to minimum Tubes are clogged Sediment or Carbon filter is blocked or excessively dirty Water pre...

Страница 23: ...ounces R 134a Input Voltage 115 VAC 60 HZ SINGLE PHASE Amperage 10 AMPS FLA Minimum Ambient Temperature 40 F 4 5 C Maximum Ambient Temperature 104 F 43 C Inlet Water Pressure 30 PSI 120 PSI SINGLE PHA...