7.
Reconnect the modules you disconnected in step 4.a using Mini-SAS HD(m)-to-Mini-
SAS HD(m) (18 in.) cables.
a)
Connect the PORT 4 connector of the PXIe-7902 front panel in slot 9 of the RX or
RX/TX chassis to the PORT 4 connector of the PXIe-7902 front panel in slot 9 of
the coding chassis.
b)
Connect the PORT 4 connector of the PXIe-7902 front panel in slot 18 of the RX or
RX/TX chassis to the PORT 5 connector of the PXIe-7902 front panel in slot 9 of
the coding chassis.
8.
If you chose to remove the third cable in step 4.b, replace it now by using a Mini-SAS
HD(m)-to-Mini-SAS HD(m) (8.25 in.) cable to connect the PORT 5 connector of the
PXIe-7902 front panel in slot 9 of the RX or RX/TX chassis to the PORT 5 connector of
the PXIe-7902 front panel in slot 18 of the RX or RX/TX chassis.
9.
Connect the PORT 1 connector of the PXIe-7902 front panel in slot 9 of the coding
chassis to the PORT 1 connector of the PXIe-7902 front panel in slot 18 of the coding
chassis using a Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) cable.
10. Power on the chassis.
11. If you have a bidirectional system, repeat steps 1 through 10 for the second set of chassis.