Figure 17. Unidirectional MIMO (Baseband and IF) RX Chassis
NI PXIe-3620
IF-LO Module, 2 GHz BW
TX
LO1
IN
LO1
IF OUT
IF IN
IF SYNC IN
IF SYNC OUT
REF IN
REF OUT
LO2 OUT
ESD
SENSITIVE
LO2 IN
I+
I–
Q+
Q–
I+
I–
Q+
Q–
DIGITAL I/O
LVTTL
LO1
LO1
OUT
LO1
IN
LO1
OUT
RX
mmWave
PXIe-7902
CLK
IN
POR
T
2
POR
T
3
POR
T
4
POR
T
5
POR
T
0
POR
T
1
PXIe-3630
I/Q Digitizer
REF IN
+10 dBm
NOM
+13 dBm
MAX
1.5 Vp-p
DIFF MAX
1.5 Vp-p
DIFF MAX
0 Vcm
ALL PORTS 50
Ω
REF
OUT
0
1
2
3
Q+
Q–
I+
I–
ACCESS
ACTIVE
NI PXIe-3620
IF-LO Module, 2 GHz BW
TX
LO1
IN
LO1
IF OUT
IF IN
IF SYNC IN
IF SYNC OUT
REF IN
REF OUT
LO2 OUT
ESD
SENSITIVE
LO2 IN
I+
I–
Q+
Q–
I+
I–
Q+
Q–
DIGITAL I/O
LVTTL
LO1
LO1
OUT
LO1
IN
LO1
OUT
RX
mmWave
PXIe-7902
CLK
IN
POR
T
2
POR
T
3
POR
T
4
POR
T
5
POR
T
0
POR
T
1
PXIe-3630
I/Q Digitizer
REF IN
+10 dBm
NOM
+13 dBm
MAX
1.5 Vp-p
DIFF MAX
1.5 Vp-p
DIFF MAX
0 Vcm
ALL PORTS 50
Ω
REF
OUT
0
1
2
3
Q+
Q–
I+
I–
ACCESS
ACTIVE
2
1
3
4
5
6
7
8
9
11
12
13
14
15
16
17
18
10
NI PXIe-1085
10 MHz REF OUT
IN
24 GB/s
Embedded Controller
RESET
TRIG
ACT/
LINK
ACT/
LINK
2
1
10/100
/1000
10/100
/1000
USER1
USER2
PWR OK/
FAULT
DRIVE
GPIB
PXIe-7902
CLK
IN
POR
T
2
POR
T
3
POR
T
4
POR
T
5
POR
T
0
POR
T
1
1
2
3
1. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) Cables
2. MMPX(m)-to-MMPX(m) Cables
3. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) Cables
5.
Connect the adjoining PXIe-3610 and PXIe-3620 modules in the TX chassis using four
MMPX(m)-to-MMPX(m) cables.
a)
Connect the I+ connector of the PXIe-3610 front panel to the TX I+ connector of the
PXIe-3620 front panel.
b)
Connect the I– connector of the PXIe-3610 front panel to the TX I– connector of the
PXIe-3620 front panel.
c)
Connect the Q+ connector of the PXIe-3610 front panel to the TX Q+ connector of
the PXIe-3620 front panel.
d)
Connect the Q– connector of the PXIe-3610 front panel to the TX Q– connector of
the PXIe-3620 front panel.
6.
Connect the adjoining PXIe-7902 and PXIe-3610 modules in the TX chassis using four
Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) cables.
a)
Connect the PORT 0 connector of the PXIe-7902 front panel to the 0 connector of
the PXIe-3610 front panel.
b)
Connect the PORT 1 connector of the PXIe-7902 front panel to the 1 connector of
the PXIe-3610 front panel.
c)
Connect the PORT 2 connector of the PXIe-7902 front panel to the 2 connector of
the PXIe-3610 front panel.
d)
Connect the PORT 3 connector of the PXIe-7902 front panel to the 3 connector of
the PXIe-3610 front panel.
mmWave Transceiver System Getting Started Guide
|
© National Instruments
|
25