background image

What If I Can’t See The Video?

This problem usually results from having the video card output set past the monitor

limits. To resolve the problem, start Windows in Safe Mode by rebooting the

controller. As Windows begins to restart, hold down <F8>. You now should be able to

reset the video driver to lower settings. Try setting the resolution to 800 × 600 and

the refresh rate to 60 Hz. Once you restart, you can raise these values again, using
the test option in Windows. You can access these settings by clicking 

Adjust screen

resolution

 in the 

Appearance and Personalization

 category of the 

Control

Panel

. You also can try a different monitor, preferably a newer and larger one.

My system boots fine as long as a particular module is not in my

chassis. How do I boot the chassis with the module installed?

The most common cause of this problem is a damaged module. Try the module in a

different chassis or with a different controller. Also, remove any external cables or

terminal blocks connected to the system. If the module does not work in these

cases, it is likely damaged. Contact the module manufacturer for further

troubleshooting.

My chassis or controller does not appear in MAX. How do I use MAX

to identify and configure my PXI system?

If you are using MAX to configure your PXI system, you must install the PXI Platform

Services software on your controller to identify NI PXI and PXI Express chassis and

modules in MAX. You can install PXI Platform Services from the software CD included

with your controller or from 

ni.com/downloads

.

My CMOS is corrupted. How do I set it back to default?

There are two methods that you can use to reset the CMOS.

1. First Method

1. Enter the BIOS setup program as described in the Accessing BIOS

Setup Utility section of the NI PXIe-8840 Quad-Core User Manual for

more information.

ni.com

22

PXIe-8840 Quad Core

Содержание NI PXIe-8840

Страница 1: ...PXIe 8840 Quad Core 2022 07 20...

Страница 2: ...s 15 General Questions 15 Boot Options 16 Cables and Connections 17 Software Driver Installation 18 Upgrade Information 19 PXI Configuration 20 Troubleshooting 20 What if the Controller Does Not Boot...

Страница 3: ...t specifications These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment This prod...

Страница 4: ...unded object such as your computer chassis and complete the following steps 1 Touch the antistatic package to a metal part of the chassis before removing the device from the package Caution Never touc...

Страница 5: ...temperature limit Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Maximum altitude 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree 2 Indoor use o...

Страница 6: ...ion To protect both yourself and the chassis from electrical hazards leave the chassis off until you finish installing the NI PXIe 8840 Quad Core 2 Remove any panels blocking access to the system cont...

Страница 7: ...the NI PXIe 8840 Quad Core to the chassis 9 Check the installation 10 Connect the keyboard and mouse to the appropriate connectors If you are using a PS 2 keyboard and a PS 2 mouse a Y splitter adapt...

Страница 8: ...settings and install LabVIEW Real Time software Complete the following steps to install the LabVIEW RT software 1 Boot the NI PXI Express embedded controller into the real time operating system Refer...

Страница 9: ...appropriate PXI Express controller entry to access the Network Settings tab in the right pane view 4 Optional Enter a name for the RT target in the Name text box 5 Optional Set the network configurat...

Страница 10: ...EW RT configuration switches to configure LabVIEW RT if it is installed on the controller If you are not using LabVIEW RT these switches should remain in the OFF position The controller reads these sw...

Страница 11: ...nnect to the network using DHCP If the target cannot initiate a DHCP connection the target connects to the network with a link local IP address or 169 254 x x The following figure shows the location o...

Страница 12: ...These files and directories are copied exactly from the manufacturer distribution disks so the naming conventions vary from peripheral to peripheral The NIDRIVERS directory contains the GPIB and PXI P...

Страница 13: ...ant Only Front Panel Connectors The following table lists various peripherals and their corresponding NI PXIe 8840 Quad Core external connectors bus interfaces and functions Peripheral External Connec...

Страница 14: ...tion process is needed to prevent two resources from connecting to the same trigger line resulting in the trigger being double driven and possibly damaging the hardware At the time of this manual s pu...

Страница 15: ...remove the NI PXIe 8840 Quad Core from a PXI Express chassis complete the following steps 1 Power off the chassis 2 Remove any cables that may be attached to the controller front panel 3 Unscrew the f...

Страница 16: ...ve at the same time Yes Refer to the BIOS Setup Utility section of the NI PXIe 8840 Quad Core User Manual for more information What devices can I boot from The NI PXIe 8840 Quad Core can boot from the...

Страница 17: ...while booting After the BIOS completes the POST and just before the controller boots the OS the Boot menu is displayed You can select the device type you want to boot from How do I plug both a PS 2 mo...

Страница 18: ...Base 3H3COSD8 What Peripheral Drivers Should I Use with My PXI or VXI Controller at ni com support How do I install or reinstall the GPIB driver The NI 488 2 driver for your GPIB port is installed by...

Страница 19: ...8840 Quad Core from the PXI chassis 2 Locate the DDR3L SO DIMM module on the side of the controller as shown in the following figure 3 Install the new DDR3L SO DIMM module into the slot NI PXIe 8840...

Страница 20: ...est software drivers The latest National Instruments software is available from ni com downloads For peripheral drivers refer to KnowledgeBase 3H3COSD8 What Peripheral Drivers Should I Use with My PXI...

Страница 21: ...nical support What has changed about the system Did you recently move the system Was there electrical storm activity Did you recently add a new module memory chip or piece of software Refer to your ch...

Страница 22: ...of this problem is a damaged module Try the module in a different chassis or with a different controller Also remove any external cables or terminal blocks connected to the system If the module does n...

Страница 23: ...CMOS button SW1 for 2 to 3 seconds as shown in the following figure 4 Reinstall the controller in the chassis Figure 7 Clearing the CMOS Contents 1 1 Push Button Switch SW1 Worldwide Support and Serv...

Страница 24: ...y EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni...