Switch 4—
Reset IP Address
: Set this switch to ON to reset the IP address
and other TCP/IP settings to their factory defaults. Use this switch if moving
the controller to a different subnet or if the current TCP/IP settings are invalid.
Note
By default, the target automatically attempts to connect to the
network using DHCP. If the target cannot initiate a DHCP connection, the
target connects to the network with a link-local IP address or 169.254.x.x.
The following figure shows the location of the LabVIEW RT configuration switches.
The switches are shown in the OFF position.
Figure 3. LabVIEW RT Configuration Switches
3
2
1
4
1. Switch 1—Boot LabVIEW RT
2. Switch 2—Boot Safe Mode
3. Switch 3—Disable Startup VI
4. Switch 4—Reset IP Address
© National Instruments
11
PXIe-8840 Quad Core
Содержание NI PXIe-8840
Страница 1: ...PXIe 8840 Quad Core 2022 07 20...