National Instruments Direct Injector Driver System Manual
© 2013 National Instruments. All rights reserved.
TMP-OneShot_DIX_ChnX
Tip Strip: Manually triggers TMP injection command sequence
Detail: Pressing this button will trigger the configured TMP command sequence to the associated DI Driver
module channel. The sequence will be triggered once with each button press.
Enable Individual DIX Channel Duration
Tip Strip: Enables individual channel duration setpoint for each channel
Detail: When
ON,
this button will enables individual channel durations for each if the three DI Driver module
channels. When
OFF,
each channel receives a uniform duration command.
Pulse #
Tip Strip: Enables injection pulse
Detail: When
ON
, the command to the associated DI Driver module channel will be active for the specified
duration. When
OFF
, the command will be inactive (low), but the specified delay and duration will still be
implemented without effecting the adjacent pulses.
Delay
Tip Strip: Time until beginning of this injection pulse
Units: msec
Detail: For Inj 1, specifies the delay of the start of Inj 1 from the trigger event. For all other pulses, specifies
the delay of the start of Inj X from the end of the previous pulse.
Uniform Duration/Ch1 Duration
Tip Strip: Duration of injection pulse
Units: msec