National Instruments Direct Injector Driver System Manual
© 2013 National Instruments. All rights reserved.
Duration Ch1 (msec)
Tip Strip: Duration of injection pulse
Units: msec
Detail: Time duration of the EPT mode injection pulse. The
ON/OFF
parameter determines whether the pulse will be active or inactive.
Duration Ch1 (CAD)
Tip Strip: Duration of injection pulse
Units: CAD
Detail: This parameter is always disabled but automatically updated with a calculated crank angle degrees
duration value. It is calculated based on
Tab of the
Setup window.
Duration Ch2-4 (msec) and (CAD)
Tip Strip: Duration of injection pulse
Units: msec and CAD
Detail: See information for
SkipFire_PFI_ChnX
Tip Strip: Enables Skip Fire on selected DI channel when EPT Mode is selected.
Detail: Enables the skip fire sequence defined by
for its
assigned PFI channel.
PFI1_SkipFire_Cycles
Tip Strip: Specifies the period length, in number of cycles, for the skip fire sequence in EPT Mode (Min = 1).
Detail: Specifies the number of cycles included in a skip fire sequence when the PFI injector is operated in
EPT mode. For example, if the number 7 is entered, the PFI injector will continuously repeat a seven cycle
is enabled for the desired channel.