Init_AIX_Filt
Tip Strip: Re-intialize filter to change break frequency
Detail: When pressed, reinitializes the 2
nd
order filter on
. The filter should be reinitialized when
changing
.
AIX_FilterBreak
Tip Strip: Filter cutoff frequency
Units: Hz
Detail: Lowpass cutoff frequency of a 2
nd
order filter on raw voltage.
SimEnable_AIX
Tip Strip: Enable simulation of this parameter in engineering units
Detail: When TRUE, passes the
directly to
, bypassing the filter and conversion lookup table.
This is useful for tuning PID control gains when
is being used for feedback control.
Sim_AIX
Tip Strip: Simulation value
Detail: The value, in engineering units, that is simulated when
ENABLED
.