National Instruments Direct Injector Driver System Manual
© 2013 National Instruments. All rights reserved.
Detail: When pressed, the PFI Driver module will deliver a one-shot pulse to the PFI channel selected in
, having a duration specified by
This button returns to the
OFF
state
automatically.
PFI_OneShotSelect
Tip Strip: Selects channel for one-shot command
Detail:
selects the PFI Driver channel to which a one-shot pulse is delivered. To disable
one-shot functionality, set to
Disabled
.
PFI_OneShotTime
Tip Strip: Duration of one-shot command
Units:msec
Detail: Duration of one-shot pulses.
PFI_FaultClear
Tip Strip: Clear PFI module short-circuit faults
Detail: When this one-shot is pressed, all critical faults of the PFI Driver module will be cleared.
ShortCircuitFaults
Tip Strip: Lowside channel short-circuit fault