National Instruments Direct Injector Driver System Manual
© 2013 National Instruments. All rights reserved.
Detail: Specifies the operating point which will be executed upon an error condition. This parameter is only
is set to
Goto Error State
Goto Error State
, and
is
FALSE
.
Number of OP Loops
Tip Strip: Number of operating point loops to execute. 0 = continuous.
Detail: Specifies the number of times to execute the complete set of operating points. A special value of zero
means that the cycle will repeat continuously. This parameter is only applicable to
OP Loops Completed
Tip Strip: Indicates the number of operating point loops completed. This parameter is only applicable to
.
OP Mode
Tip Strip: Mode of executing operating points
Detail:
Timer Mode:
Executes the number of points specified by
sequentially, according to the
value associated with each operating point.
Trigger Mode:
Executes the operating point specified by the selected
and their
associated
.
Current Time/Trigger
Units: msec
Detail: Indicates the current timer value. This parameter is only applicable in
.
Detail: Indicates the active trigger wildcard. This parameter is only applicable in
.