background image

Worldwide Support and Services

The National Instruments website is your complete resource for technical support. At 

ni.com/

support

 you have access to everything from troubleshooting and application development self-

help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and

other services.

Visit 

ni.com/register

 to register your National Instruments product. Product registration

facilitates technical support and ensures that you receive important information updates from
NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway,
Austin, Texas, 78759-3504. National Instruments also has offices located around the world.
For telephone support in the United States, create your service request at 

ni.com/support

 or

dial 512 795 8248. For telephone support outside the United States, visit the 

Worldwide

Offices

 section of 

ni.com/niglobal

 to access the branch office websites, which provide up-to-

date contact information, support phone numbers, email addresses, and current events.

Installing PXI EMC Filler Panels

To ensure specified EMC performance, PXI EMC filler panels must be properly installed in
your NI FlexRIO system. The PXI EMC filler panels (National Instruments part number
778700-01) must be purchased separately. For more installation information, refer to the

NI FlexRIO FPGA Module Installation Guide and Specifications

.

1. Remove the captive screw covers.
2. Install the PXI EMC filler panels by securing the captive mounting screws to the chassis,

as shown in the figure below. Make sure that the EMC gasket is on the right side of the

PXI EMC filler panel.

NI 5772R User Manual and Specifications

 | © National Instruments | 33

Содержание NI 5772R

Страница 1: ...NI 5772...

Страница 2: ...and the NI 5772 This document also contains tutorial sections that demonstrate how to acquire data using a LabVIEW FPGA Example VI and how to create and run your own LabVIEW project with the NI 5772R...

Страница 3: ...se requirements and limits are designed to provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment This product...

Страница 4: ...anels on page 33 Connecting Cables 1 Use any shielded 50 SMA cable to connect signals to the connectors on the front panel of your device 2 Use the SHH19 H19 AUX cable NI part number 152629 01 or 1526...

Страница 5: ...le from the Start menu and at ni com manuals Contains installation instructions for your NI FlexRIO system and specifications for your FPGA module NI 5772R User Manual and Specifications this document...

Страница 6: ...tion and data sheets for NI FlexRIO devices Front Panel and Connector Pinouts Table 2 shows the front panel connector and signal descriptions for the NI 5772 Caution To avoid permanent damage to the N...

Страница 7: ...AI 0 Analog input channel 0 50 single ended AI 1 Analog input channel 1 50 single ended TRIG Trigger input and output channel AUX I O Refer to Table 3 for the signal list and descriptions Caution Conn...

Страница 8: ...irectional SE DIO data channel 10 DIO Port 1 2 Bidirectional SE DIO data channel 11 GND Ground reference for signals 12 DIO Port 1 3 Bidirectional SE DIO data channel 13 PFI 0 Bidirectional SE DIO dat...

Страница 9: ...DC12D800RF DIO Port 1 WE Request DIO Port 1 Rd Data 0 3 DIO Port 1 Wr Data 0 3 DIO Port 1 WE Actual PFI 0 3 WE PFI 0 3 Rd Data PFI 0 3 Wr Data DIO Port 0 WE Request DIO Port 0 Rd Data 0 3 DIO Port 0 W...

Страница 10: ...l to the FPGA Adapter module socketed CLIP allows your IP to communicate directly with both the FPGA VI and the external adapter module connector interface The following figure shows the relationship...

Страница 11: ...e grouped into two ports of four signals each and are accessed using a U8 data type and a Boolean write enable signal The four PFI signals are accessed individually using Boolean indicators Although r...

Страница 12: ...e Clock locked to an external Reference Clock through the REF IN connector Internal Sample Clock locked to an external Reference Clock though IoModSyncClock This CLIP also enables the user to synchron...

Страница 13: ...A embedded in the hardware At least one VI that runs on Windows and interacts with the LabVIEW FPGA VI Note In the LabVIEW FPGA Module software NI FlexRIO adapter modules are referred to as IO Modules...

Страница 14: ...select either Software or Data Edge If you select Software the VI acquires data every time you click the Software Trigger front panel button If you select Data Edge the VI acquires data every time an...

Страница 15: ...dule list The available CLIP for the NI 5772 is displayed in the General category of the Component Level IP pane If the information in the General category is dimmed select the Enable IO Module checkb...

Страница 16: ...pen FPGA VI Reference 5 In the Configure Open FPGA VI Reference dialog box select VI in the Open section 6 In the Select VI dialog box that opens select 5772SampleAcq FPGA vi under your device and cli...

Страница 17: ...function 18 Wire the error out output of the Read Write Control function to the error in input of the Close FPGA VI Reference function Your block diagram should now resemble the block diagram in the f...

Страница 18: ...IN front panel connector Note Do not connect an external Sample Clock with a frequency greater than 800 MHz to the CLK IN front panel connector to acquire data at rates greater than 800 MS s Instead u...

Страница 19: ...d Chassis fan speed is set to High In addition NI recommends using slot blockers and EMC filler panels in empty module slots to minimize temperature drift The NI 5772 uses NI LabVIEW and LabVIEW FPGA...

Страница 20: ...data4 ADC part number ADC12D800RF5 Absolute maximum voltage 10 VDC 21 dBm 7 1 Vpk pk Typical Specifications All specifications were tested in TIS Disabled mode unless otherwise specified DC offset AC...

Страница 21: ...tude at 10 MHz 3 dB 1 dB AC coupled 110 kHz 240 kHz DC coupled 0 kHz 0 kHz Table 9 Bandwidth And Spectral Performance Summary Mode Coupling Bandwidth 3 dB Bandwidth 1 dB SNR dB SFDR dBc THD dBc ENOB b...

Страница 22: ...upled N A N A N A N A N A N A Measured using a 1 dBFS signal at 187 MHz Related Information Analog Input Impedance on page 21 Analog Input Impedance Analog Input Impedance Figure 9 Analog Input Return...

Страница 23: ...G 2 G 2 4 G 0 9 10 M 1 8 Frequency Response Note Referenced at 10 MHz using 9 dBm Figure 11 AC Low Frequency Response Referenced to Amplitude at 10 MHz Frequency Hz Amplitude Response dB 6 0 7 0 3 0...

Страница 24: ...bled Non Muxed DC TIS Disabled Frequency Hz Amplitude Response dB Figure 13 DC Bandwidth Referenced to Amplitude at 10 MHz 100 0 200M 400M 600M 800M 1G 1 2G 1 4G 1 6G 95 90 85 80 75 70 65 60 55 50 45...

Страница 25: ...0 4 5 4 0 3 5 3 0 2 5 2 0 1 5 1 0 0 5 0 0 1 5 1 0 DC Ch0 TIS Disabled DC Ch1 TIS Disabled DC Ch0 TIS Enabled DC Ch1 TIS Enabled Spectral Measurements Figure 15 Noise Density Frequency Hz Noise Density...

Страница 26: ...20 M 400 M 0 20 30 40 10 0 70 60 50 90 80 110 100 10 Figure 17 Two Tone Spectral Measurement TIS Multiplexed Mode 182k Samples 10 Averages Frequency Hz Amplitude dBm 20 30 40 10 0 70 60 50 90 80 160 M...

Страница 27: ...IoModSyncClock Locked to Front Panel Free Running Uses a 10 MHz Wenzel OCXO P N 501 04609A as the reference signal Crosstalk Figure 19 AI Crosstalk Aggressor at 1 dBFS Victim Terminated to 50 7 Input...

Страница 28: ...DC Ch0 Aggressor Ch1 Victim DC Ch1 Aggressor Ch0 Victim Input Frequncy Hz Cross Talk dB Related Information Typical Specifications on page 19 Internal Sample Clock General Characteristics PLL part num...

Страница 29: ...dBm 7 1 Vpk pk Duty cycle 30 to 70 REF IN General Characteristics Number of channels 1 single ended Connector type SMA Frequency 10 MHz Input impedance 50 Input coupling AC Input voltage range 2 dBm 8...

Страница 30: ...ce logic Maximum VIL 0 8 V Maximum VIH 2 0 V Maximum VOL 0 4 V Minimum VOH 2 7 V Maximum VOH 3 6 V Zout 50 20 Iout DC 2 mA Pull down resistor 150 k Recommended operating voltage 0 3 V to 3 6 V Overvol...

Страница 31: ...ush Make sure that the hardware is completely dry and free from contaminants before returning it to service Environment Maximum altitude 2 000 m at 25 C ambient temperature Pollution Degree 2 Indoor u...

Страница 32: ...of the following electrical equipment safety standards for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CSA 61010 1 Note For UL and other safety certifications refer to the...

Страница 33: ...committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the...

Страница 34: ...ct at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world F...

Страница 35: ...uments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to th...

Отзывы: