manualshive.com logo in svg
background image

 

 

 

 

National Instruments CVS-1459RT Manual 

Get Pricing & Availability at 

 

ApexWaves.com 

 

Call Today: 1-800-915-6216 

Email: 

[email protected]

 

 

 

 

 

https://www.apexwaves.com/modular-systems/national-instruments/cvs-1450-series/CVS-1459RT

 

 

Содержание CVS-1459RT

Страница 1: ...nstruments CVS 1459RT Manual Get Pricing Availability at ApexWaves com Call Today 1 800 915 6216 Email sales apexwaves com https www apexwaves com modular systems national instruments cvs 1450 series...

Страница 2: ...NI Vision NI CVS 1459RT User Manual Compact Vision System with USB3 Vision and Reconfigurable I O NI CVS 1459RT User Manual September 2014 374248A 01...

Страница 3: ...ers email addresses and current events National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin Texas 78759 3504 USA Tel 512 683 0100 For further support information refer to th...

Страница 4: ...TNESS FOR A PARTICULAR PURPOSE TITLE OR NON INFRINGEMENT AND ANY WARRANTIES THAT MAY ARISE FROM USAGE OF TRADE OR COURSE OF DEALING NI DOES NOT WARRANT GUARANTEE OR MAKE ANY REPRESENTATIONS REGARDING...

Страница 5: ...es independent from National Instruments and have no agency partnership or joint venture relationship with National Instruments Patents For patents covering National Instruments products technology re...

Страница 6: ...r more of the following measures Reorient the antenna of the receiver the device suffering interference Relocate the transmitter the device generating interference with respect to the receiver Plug th...

Страница 7: ...Inspection 1 3 LabVIEW 1 3 LabVIEW Real Time Module 1 3 LabVIEW FPGA Module 1 3 NI Vision Development Module 1 3 NI Vision Acquisition Software 1 4 Chapter 2 LED Indicators and the RESET Button LED In...

Страница 8: ...Boot Menu 5 3 Boot Settings Configuration Submenu 5 4 Device BBS Priority Submenus 5 4 Save Exit Menu 5 5 Restoring the NI CVS 1459RT to Factory Default Condition 5 6 Appendix A Troubleshooting Softwa...

Страница 9: ...hat is a placeholder for a word or value that you must supply monospace Text in this font denotes text or characters that you should enter from the keyboard sections of code programming examples and s...

Страница 10: ...on Interface Resources for NI LabVIEW NI Vision Development Module and NI Vision Acquisition Software Users Documentation for LabVIEW the LabVIEW Real Time Module and the LabVIEW FPGA Module is availa...

Страница 11: ...puter allows you to display measurement results and status information and to configure the NI CVS 1459RT settings When configured the NI CVS 1459RT can run applications without a connection to the de...

Страница 12: ...figurations are referred to as hardware personalities and are defined by bitfiles Use the following software to use and reconfigure the FPGA I O LabVIEW FPGA Module 2012 or later You must install the...

Страница 13: ...ions if necessary Vision Builder AI allows you to remotely configure and control the NI CVS 1459RT LabVIEW LabVIEW is a graphical programming environment for developing flexible and scalable applicati...

Страница 14: ...Vision Acquisition Software which contains all of the drivers in the NI Vision product line With NI Vision Acquisition Software you can quickly and easily start your applications without having to pro...

Страница 15: ...tion and functionality of the LED indicators and the RESET button on the NI CVS 1459RT LED Indicators Figure 2 1 shows the LEDs on the NI CVS 1459RT Figure 2 1 LED Indicators NI CVS 1459RT Compact Vis...

Страница 16: ...information about installing software 3 blinks The NI CVS 1459RT has booted into safe mode Refer to the Safe Mode section for information about the safe mode state 4 blinks The NI CVS 1459RT has expe...

Страница 17: ...VS 1459RT and the development computer Figure 2 2 LEDs for the Primary Gigabit Ethernet Network Port Refer to Table 2 3 for information on the Ethernet LED indications Table 2 2 PWR FAULT LED Indicati...

Страница 18: ...ivity 1 Hold the RESET button for 5 seconds and then release it to boot the NI CVS 1459RT into safe mode 2 After booting the controller into safe mode hold the RESET button again for 5 seconds to enab...

Страница 19: ...r or when the current TCP IP settings are invalid When the NI CVS 1459RT is in the IP reset state the IP address of the network port resets to DHCP or a link local address You can then set up a new ne...

Страница 20: ...sition SYSTEM power connector System power 2 position ISO power connector Power to isolated outputs RJ45 10 100 1000 Ethernet port Network connection USB 2 0 Standard A receptacles High retention USB...

Страница 21: ...1 NI CVS 1459RT Front Panel Connectors 1 VGA Connector 2 RJ50 Serial Port 3 USB 2 0 Ports 4 RJ45 Gigabit Ethernet Network Port 5 USB3 Vision Ports 6 44 pin Digital I O Connector NI CVS 1459RT Compact...

Страница 22: ...on the NI CVS 1459RT shown in Figure 3 2 to connect the chassis to earth ground An earth ground connection is optional Note An earth ground connection does not connect C or CISO to earth ground Figure...

Страница 23: ...e power connectors Figure 3 3 Power Connectors Table 3 2 describes the terminals on the power connectors 1 System Power Connector 2 Isolated Outputs Power Connector Table 3 2 Power Connector Terminals...

Страница 24: ...er electrical standards required for Gigabit Ethernet communication CAT 5 cables are not guaranteed to meet the necessary requirements While CAT 5 cables may appear to work at 1 000 Mbps CAT 5 cables...

Страница 25: ...inout Table 3 4 lists and describes the USB connector signals RS 485 422 232 Serial Port The NI CVS 1459RT has a single serial port that can operate in either RS 485 422 mode or RS 232 mode Set the se...

Страница 26: ...esolution of 1920 x 1200 at 60 Hz You can develop a single real time VI to use for both your user interface and system logic For more information refer to the Using the Embedded UI to Access RT Target...

Страница 27: ...eo signal 3 BLUE Blue analog video signal 4 RESERVED Reserved 5 GND Ground reference 6 RED RETURN Ground reference 7 GREEN RETURN Ground reference 8 BLUE RETURN Ground reference 9 PWR 5 V power for DD...

Страница 28: ...X drive starting with the U drive if it is available Refer to the LabVIEW Help for more information Figure 3 8 shows the pinout for the USB 3 0 connectors Figure 3 8 USB3 Vision Port Pin Locations Tab...

Страница 29: ...3 TTL 0 Bidirectional TTL I O 4 TTL 1 Bidirectional TTL I O 5 GND Digital ground reference for TTL and differential I O 6 TTL 2 Bidirectional TTL I O 7 TTL 3 Bidirectional TTL I O 8 GND Digital ground...

Страница 30: ...ted input 32 Iso In 1 General purpose isolated input 33 CISO Common ground reference for isolated inputs and outputs 34 Iso In 2 General purpose isolated input 35 Iso In 3 General purpose isolated inp...

Страница 31: ...n Isolated Input to a Sourcing Output Device Wiring an Isolated Output The digital output circuit sources current to external loads as shown in Figure 3 10 Caution Do not draw more than 35 mA each fro...

Страница 32: ...d cables for all applications Unshielded cables are more susceptible to noise and can corrupt signals Figure 3 11 shows the differential input quadrature encoder input circuit Figure 3 12 and Figure 3...

Страница 33: ...Drivers Figure 3 13 Connecting Single Ended Line Drivers Diff In 0 Diff In 0 Phase A Phase A Diff In 1 Diff In 1 Phase B Phase B Encoder NI CVS 1459RT Twisted Pair Twisted Pair Diff In 0 Diff In 0 Pha...

Страница 34: ...ational Instruments 3 15 NI CVS 1459RT User Manual TTL I O Figure 3 14 shows the circuit for a bidirectional TTL I O Figure 3 14 TTL Input Output Circuit 100 TTL_OUT 0 TTL_OE 0 TTL_IN 0 10 k FB TTL I...

Страница 35: ...devices to the same network as shown in Figure 4 1 Figure 4 1 Multiple NI CVS 1459RT Devices Connected to the Same Network To connect multiple NI CVS 1459RT devices to the same network each device mus...

Страница 36: ...ion environment The default name for each device is NI CVS1459RT XXXXXXXX where XXXXXXXX is the eight digit serial number When configured to run an inspection the NI CVS 1459RT can run autonomously wi...

Страница 37: ...the BIOS setup program and display the Main menu Use the following keys to navigate through the BIOS setup Left right up and down arrows Use these keys to move between different setup menus Press Esc...

Страница 38: ...vanced setup menu includes the following settings Power Wake Configuration Use this setting to bring up the Power Wake Configuration submenu For information about the menu items within this submenu re...

Страница 39: ...bles or disables operating system notifications of USB overcurrent events The default is Disabled Transfer Timeout Specifies the number of seconds the POST waits for a USB mass storage device to compl...

Страница 40: ...he Device BBS Priorities submenus to re order the priority of devices of the same type Boot Settings Configuration Submenu Setup Prompt Timeout This setting specifies the amount of time the system wai...

Страница 41: ...ork devices The highest priority device is displayed on the main Boot Option Priorities list Optionally each device can also be Disabled if the device should never be used as a boot device Save Exit M...

Страница 42: ...ing to the selected device without first rebooting If BIOS setup options have been changed and saved a reboot is required and the boot override selection will not be valid Restoring the NI CVS 1459RT...

Страница 43: ...you assign the same static IP to two devices you assign a static IP that is in the range of the IP address available for DHCP use on your network or the DHCP server assigns the same IP address to ano...

Страница 44: ...o software is installed install application and driver software on the NI CVS 1459RT Refer to the NI CVS 1459RT Getting Started Guide for installation instructions No Camera Found Verify that the came...

Страница 45: ...IEW Real Time engine LED Error Indications The NI CVS 1459RT indicates specific error conditions by flashing the STATUS LED a specific number of times Refer to STATUS LED section of Chapter 2 LED Indi...

Страница 46: ...le from National Instruments part number 781740 01 Figures B 1 through B 4 provide dimensional drawings and clearance information for the NI CVS 1459RT Caution If you choose not to mount the NI CVS 14...

Страница 47: ...B 2 ni com Appendix B Mounting Information Figure B 1 Front View of the NI CVS 1459RT with Dimensions in inches millimeters...

Страница 48: ...Dimensions in inches millimeters Note You can ground the NI CVS 1459RT to your mount by connecting a grounding wire to the chassis grounding screw on the NI CVS 1459RT Refer to the Chassis Grounding S...

Страница 49: ...B 4 ni com Appendix B Mounting Information Figure B 3 Side View of the NI CVS 1459RT with Dimensions 5 133 in 130 38 mm 4 270 in 108 47 mm 150 in 3 80 mm 4 121 in 104 67 mm...

Страница 50: ...in lb Make sure the heads of the screws are flush with the mounting bracket Clearance Requirements The NI CVS 1459RT installation must meet the following space and cabling clearance requirements for o...

Страница 51: ...learance requirements for the NI CVS 1459RT Figure B 5 Clearance Requirements for the NI CVS 1459RT 50 8 mm 2 00 in 50 8 mm 2 00 in 76 2 mm 3 00 in 76 2 mm 3 00 in NI CVS 1459RT Compact Vision System...

Страница 52: ...you identify your systems accuracy and reliability requirements and provides warranty sparing and calibration services to help you maintain accuracy and minimize downtime over the life of your system...

Страница 53: ...ake sure every question submitted online receives an answer Software Support Service Membership The Standard Service Program SSP is a renewable one year subscription included with almost every NI soft...

Отзывы: