© National Instruments Corporation
A-1
SCXI-1100 User Manual
Appendix A
Specifications
This appendix lists the specifications for the SCXI-1100. These are typical at 25
°
C unless
otherwise stated. The operating temperature range is 0
°
to 50
°
C.
Analog Input
Number of channels
32 differential
Analog input range
1
±
10 V
Instrumentation amplifier
Input bias current
±
350 pA
Input offset current
±
350 pA
Gain (software-selectable)
1, 2, 5, 10, 20, 50, 100, 200, 500, 1,000, 2,000
Input impedance
>1 G
Ω
Settling time (with 10 V step)
Full bandwidth
Accuracy
Gain
1-100
200
500
1,000
2,000
0.012%
2
6
µ
s
7
µ
s maximum
7.5
µ
s
12
µ
s
20
µ
s
25
µ
s
0.006%
3
10
µ
s
10
µ
s
25
µ
s
26
µ
s
30
µ
s
0.0015%
3
32
µ
s
33
µ
s
40
µ
s
76
µ
s
195
µ
s
With filtering (all gains)
Accuracy
Bandwidth
10 kHz
4 Hz
0.012%
2
150
µ
s
0.35 s
0.006%
3
160
µ
s
0.4 s
0.0015%
3
200
µ
s
0.5 s
1
Includes both common-mode voltage and differential voltage
2
Combined settling time of the SCXI-1100 and the AT-MIO-16F-5
3
Combined settling time of the SCXI-1100 and the AT-MIO-16X