5.5.
Motor Diagnostic
This feature allows a technician to test the air motor function manually.
Follow the steps outlined below to access the motor diagnostic configuration menu. Upon releasing the
settings button, the LEDs will flash red on top and bottom. This is the first in the sequence of teachable
configurations. Subsequent pressing and releasing of the settings button will sequence the following
configurations in order of appearance. To register the desired configuration, press the reset button when that
configuration is displayed.
Diagnostic
Off
On
OFF
Clamp
status
Lift
status
Done
Motor Diagnostic Configurations:
Off
: This feature is disabled.
On
: This feature is enabled.
Note:
Running the motor diagnostic will disable the feature so that it can only be run once each time it is
enabled.
Motor Diagnostic Operation:
Once the reset button is released, the unit will display the power-up sequence.
Follow this procedure to test the air motor manually:
1.
LIFT function
: Press and hold the
“LIFT” button to raise the reaming bit (without spinning) until it
reaches the top position. Check that the
“LIFT” LED on the control module is green.
WARNING: the lift will operate under this condition. KEEP HANDS CLEAR of the
operating space of the reaming bit. This device is intended for one-man operation
during test.
Once the Intelliream
®
is at the top position (“LIFT” LED is green), release the “LIFT” button and the reaming
bit will maintain its position.
R
R
G
R
R/G
R
R
G
R
R/G
Press &
Release
(>11sec)