4-4
Sweep Mode Operating Instructions
4.2.2.2 Misc
Under the
Miscellanea
functions menu it is possible to activate or exclude
the
Preselector
filters, the
Pulse Limiter
, and also to enter in the
Tracking
generator
menu pressing the
RF OUT
button.
The
Preselector
is composed by a group of filters automatically selected by
the PMM 9010 while it is sweeping or anyway measuring. The aim of the
preselector is to reduce the amount of out-of-band energy entering in the
receiver, thus helping a lot in reducing intermodulation problems and similar
undesired behaviors.
It can be set either ON or OFF with the associated button, and normally it
should be always enabled.
On the top left corner of the screen the symbol “Off” or “On” will be
displayed.
The
Pulse Limiter
is a very useful device to protect the input of the receiver
from transient overvoltages. Doing conducted emission tests, quite often
there are conducted disturbances (usually associated to switching
operations in the EUT or along the line under test) which are too high and
that propagates through the LISN up to the receiver. Sometime these
disturbances cannot be seen on the receiver because they are out of
measurement bandwidth, nevertheless the associate energy is high enough
to damage the input attenuator and/or the Analog-to-Digital Converter of the
PMM 9010 (the first mixer in a traditional receiver).
This pulse limiter has an integrated 10dB attenuator and a 30 MHz low-pass
filter.
When the Pulse Limiter is selected, on the upper part of the screen the
letters
P.L.
appear next the value of the Minimum Attenuation and the
reading on the receiver is automatically corrected for the attenuation factor
of the Pulse Limiter.
Pressing the
RF OUT
button the receiver enters the Tracking generator
menu.
.
4.2.2.2.1 Tracking
generator
The
tracking generator
is an internal, high stability and accuracy, 50 Ohm
RF generator ranging from 10 Hz to 50 MHz.
Activating the
Tracking On
function the generator is always tuned at the
same PMM 9010 measurement frequency and scans the range together
with the receiver. This is the standard way a tracking generator works in all
spectrum analyzers.
If the Tracking On function is disabled, the generator becomes a CW signal
source tuned at the frequency set under the
RF OUT Freq
window.
As usual, to set a given frequency it is therefore enough to edit the value
with the soft keys and the left an right arrows, confirming the selections
entering the units value (kHz, MHz or GHz).
Pressing 0 as the first figure the decimal dot appears automatically.
In both operating modes (tracking or fixed frequency) the output level can be
set between 60,0 and 90,0 dBµV with 0,1dB steps using the
RF OUT Level
button.
If a higher or lower level is needed, the User shall adopt either an external
amplifier or an external attenuator.
The tracking generator is extremely useful for several applications: first of all
it is essential to calibrate the receiver itself thanks to the automatic internal
routines specifically developed to this extent, then it can also be used to
transform the PMM 9010 in a scalar network analyzer, helping a lot in
designing and testing RF filters, active stages and a lot of other circuits.
It is suggested to turn off the Generator to achieve the maximum
sensitivity.
Содержание PMM 9010 Series
Страница 24: ...XXIV Safety considerations This page has been left blank intentionally ...
Страница 42: ...2 10 Installation This page has been left blank intentionally ...
Страница 66: ...6 6 Manual Mode Operating Instructions This page has been left blank intentionally ...
Страница 72: ...7 6 Applications This page has been left blank intentionally ...
Страница 92: ...9 14 General Information This page has been left blank intentionally ...
Страница 112: ...10 20 Click Mode Operating Instructions This page has been left blank intentionally ...
Страница 145: ...PMM 9030 9060 9180 Frequency Extension 11 33 Screwing the N N Adapter to BL 01 connector ...
Страница 170: ...11 58 PMM 9030 9060 9180 Frequency Extension This page has been left blank intentionally ...
Страница 178: ...12 8 PMM 9010 RMA Rack Mount Adapter This page has been left blank intentionally ...
Страница 194: ...13 16 APD Mode Operating Instructions This page has been intentionally left blank ...
Страница 230: ...14 36 Remote control This page has been intentionally left blank ...
Страница 284: ...Suggerimenti Commenti Note Suggestions Comments Note ...