DO NOT USE A FLAME TO LEAK TEST.
LEAK TESTING: This must be done before initial use, annually and whenever any gas components are replaced or serviced. No
smoking while performing this test, and remove all sources of ignition. See
Leak Testing Diagram for areas to check.
1. Turn all burners controls to off. Turn supply valve on.
2. Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.
3. Bubbles will indicate a gas leak. Either tighten the loose joint or replace the part with one recommended by the dealer.
4. If the leak cannot be stopped, shut off the gas supply, disconnect it and have the barbecue inspected by your gas supplier or dealer.
Do not use the appliance until the leak has been corrected.
5. Turn off gas supply.
GAS HOOK-UP INSTRUCTIONS
CYLINDER CONNECTION: Ensure that the gas regulator hose is kink free. Remove the cap or plug from the cylinder fuel valve.
Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand tighten clockwise.
Do not use tools. Leak test all joints prior
to using the barbecue. A leak test must be performed annually, and each time a cylinder is hooked up, or if a part of the gas system
is replaced.
PROPANE CYLINDER INSTALLATION: Pull out the tank drawer (do not disengage slides). Set cylinder inside tank ring.
IMPORTANT: The regulator must be attached so that no part of the hose touches the underside of the grill. A fire will
result if these directions are ignored.
NATURAL GAS HOOK-UP: This natural gas grill is supplied with a 12ft supply hose (complete with a quick disconnect) designed
for natural gas and certified for outdoor use. The gas grill is designed to operate at an inlet pressure of 4.5 inches water column.
Piping and valves upstream of the quick disconnect are not supplied.
The quick disconnect must not be installed in an upward direction and a readily accessible manual shut-off valve must be installed
upstream of, and as close to, the quick disconnect as is feasible. The flared end of the hose must be connected to the unit as
illustrated in the
Natural Gas Hose Attachment diagram. These connections must be made by a licensed gas installer. Leak test all
joints prior to using the gas grill.
LEAK TESTING INSTRUCTIONS
Содержание VPrestige PF450
Страница 26: ...26 2 X N305 0027 2A PF450 3 X N305 0026 1 X N520 0014 ...
Страница 27: ...27 2 X N305 0027 4 X N305 0026 2B PF600 1 X N520 0013 ...
Страница 28: ...28 4 PF600 3 1 X N305 0040 4 X N570 0066 M4 X M6 ...
Страница 29: ...29 5 6 TO GAS SUPPLY HOUSE À L ARRIVÉE DE GAZ ...
Страница 30: ...30 7 8 ...
Страница 34: ...34 10 PF450 ...
Страница 38: ...38 12 PF600 ...
Страница 39: ...39 NOTES REMARQUE ...