W415-1066 / A / 03.06.12
7
2.3 gENErAL INFOrmATION
2.3.1 FEATurES
2.3.2 HEATINg SPECIFICATIONS
IMpORTANT
differences in chimney height and draft may lower overall burn times.
Approximate heating capacity up to 1,800 square feet (167 m
2
) for hmf100 (Will vary with the home's floor
plan, insulation and outside temperature).
maximum burn time up to 8 hours.
maximum bTu output per hour 65,000 bTu.
electric furnace up to 10 kw.
2.3.3 ELECTrICAL SPECIFICATIONS
fully configured furnace 6.5 amps, 120 v.
(optional electric furnace module’s up to 40 amps.)
2.3.4 OPTIONAL mOduLES
• maximum log length of 18" (457 mm)
• long burn time - up to 8 hours
• Automatic control with thermostat
• built in 1/6 hP blower
• firebrick lining for firebox creates kiln like tempera-
tures for maximum efficiency and low emissions
• manual switch for summer fan operation
DO NOT LET THE AppLIANCE BECOME HOT ENOUgH FOR ANY pART TO gLOw RED.
Optional Modules Available:
• 10 kw electric furnace module hmfk-ef10
• napoleon® diffusion Plenum hmfk-dP
certification Standards and installation codes:
ul391-2010
cSA b366.1-11
ul1995-2005/cSA c22.2 no.236-05
u.S. environmental Protection Agency (e.P.A.) certified to comply with july 1992 Particulate emission
Standards
use of this product may produce smoke which contains chemicals known to the State of california to cause
cancer, birth defects, or other reproductive harm.
rating plate is located on the inside of the front lower cover of the furnace.
2.3.5 APPLICABLE STANdArdS
2.3.6 CALIFOrNIA PrOP65
2.4 rATINg PLATE INFOrmATION
Содержание HMF100
Страница 9: ...W415 1066 A 03 06 12 9 ...
Страница 43: ...W415 1066 A 03 06 12 43 11 0 service history 43 1 ...