![NAPCO GEM-P800 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/napco/gem-p800/gem-p800_installation-instructions-manual_3286274019.webp)
19
Enhanced Communicator Features
[67] Telephone Number 1
(1) Opening After Alarm (Cancel Code)
-
When enabled, all users that are not se-
lected to report on
Opening/Closing
[39] will
report an Opening only when opening after
an alarm has occurred.
(2)
Conditional Closing Telephone 1
-
When enabled, all users that are not se-
lected to report an Opening/Closing ([39],
[59]) will report a Closing only when zones
have been bypassed. The Zone Trouble
Code [62-2] is used to report zones that
have been bypassed at the time of the clos-
ing report.
(3) Reserved
(4) Reserved
[68] Telephone Number 3
(1) Opening after Alarm (Cancel Code)
-
see [67-1].
(2) Conditional Closing Telco 3
- see
[67-1].
(3) Reserved
(4) Reserved
Wireless
Up to two receivers can be wired to the
GEM-P800. Each wireless transmitter can
be mapped to a zone. Only 1 wireless de-
vice is permitted per zone, however, the use
of both hardwired and wireless on a zone is
permitted.
To Map a transmitter to a zone:
1. Enter the Programming Block Number
that the transmitter is to be mapped to.
2. Enter the 7-digit RF ID number directly,
just as it is shown on the device label.
After the 7th digit is entered the keypad
will beep.
A transmitter will send a transmission every
time it is tripped. The transmitter also sends
a supervisory transmission about once
every hour. If the receiver does not receive
a signal from a transmitter in the time pro-
grammed in Wireless Supervisory Timer, a
system trouble 'RF Supervisory Failure' will
be indicated at the keypad.
Program Wireless Supervisory Timer [16] to
change the supervisory time from the default
of 12 hours.
The Signal strength of a transmitter can be
checked at the keypad (see
A7
Fault Find Mode) or saved to the LOG (see
Signal Strength Logging Mode - pg. 11).
[71-78] Wireless Transmitters
Enter the RF ID# and the point number that
is to be mapped to the zone.
Programming Example
Map point 1 of a window door transmitter
with an RF ID# of 0012B0:0 to Zone 3.
1. Enter Dealer Mode.
2. Enter
C
(
beeps)
73
(beeps)
3. Enter
012G200
4. Enter
1
(beeps)
Note:
If the RF ID# in step 3 is not entered
correctly the keypad will emit a 1 second
tone indicating incorrect entry. Repeat
steps 2 - 4 above.
[81] - [84] Wireless Keyfobs
The GEM-KF is a hand held wireless trans-
mitter capable of Arming and Disarming the
control panel and/or activating 2 Auxiliary
Functions. To activate the auxiliary func-
tions, press and hold the
M
or
N
key for
1.5 seconds (see WI752 for more informa-
tion).
Enter the RF ID# and AUX 1 and AUX 2
options for each Keyfob.
AUX 1 & AUX 2
Programming Options:
1 Panic
Program a 1 in the AUX 1 and/or AUX 2
option to initiate a panic alarm when the
M
or
N
buttons on the Keyfob are pressed.
Additional programming required:
Keypad Panic (
9G
) [20-3]
Panic Report to Telco 1[36-2] and/or Telco 3
[56-3].
Содержание GEM-P800
Страница 1: ...WI850E 04 10 NAPCO 2010 GEM P800 Control Panel Communicator Installation Instructions ...