18.3 STARTING AND STOP
Start the system before the air compressor starts running and stop it after the air compressor has been stopped. The
compressed air piping will be free of condensate only by doing so. The dryer must be kept running during all the time the
air compressor is running. WARNING: if the dryer is switched off, before starting it again, wait at least 5 minutes in order
to allow the pressure to balance.
BEFORE CARRYING OUT ANY MAINTENANCE JOBS IT IS MANDATORY TO STOP THE MACHINE, DISCONNECT IT FROM THE POWER
SOURCE AND ISOLATE IT FROM THE COMPRESSED AIR DISTRIBUTION NETWORK.
PRESSURE DISCHARGE PROCEDURE
Proceed as follows:
- Isolate the unit from the compressed air network
- Remove the panel Ref. 2 Fig. 11
- Release the pressure in the dryer by pressing the condensate drain “TEST” button locate on the drain Ref. 3 Fig. 11
- Switch off the machine. Turn the switch to the STOP Ref. 4 Fig. 11
- Lock-out and tag-out the unit at the fuse/breaker box
- Close the panel