ENGLISH
Cod. 9828093587 00 - Edition 11/2021 - 25
18.0 STARTING UP
BEFORE CARRYING OUT ANY OPERATION ON THE MACHINE, ENSURE THAT THE ELECTRIC POWER SUPPLY HAS
BEEN DISCONNECTED
WAIT AT LEAST TWO HOURS BEFORE STARTING UP, AFTER ANY MACHINE MOVEMENT (TRANSPORT OR
HANDLING).
18.1 PRELIMINARY CONTROLS
Before starting the dryer, check:
- The connection to the compressed air piping: remember to remove protected caps supplied on the drier inlet and outlet.
- The connection to the condensate drainage system.
- That the power supply is matches the power supply indicated on the dryer nameplate.
18.2 BELT CRANKCASE HEATER INSTRUCTION
The dryer is equipped with a belt crankcase heater that prevents refrigerant and oil mixing, refrigerant condensation in
the crankcase and refrigerant migration during the off-cycle period.
It’s strongly recommended to energize the heater AT LEAST 6 hours before to switch on the dryer.
STEP1:
connect the dryer to the main supply
STEP2:
the selector below MUST be in “HEATER ON” position
STEP3:
activate the main switch (IG) of the dryer
STEP4:
AFTER AT LEAST 6 hours move the selector belt to “DRYER ON” position
ATTENTION !
•
Repeat the four steps above each time the dryer is switched off for a prolonged period.
•
For short period of inactivity (2-3 days), keep the heater on.