![Nanni N4.40 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/nanni/n4-40/n4-40_workshop-manual_3243432040.webp)
GENERAL
03-M-E3B, 03-M-DI-E3B, 03-M-E3BG, WSM
G-25
Battery Specific Gravity
1. Measure the specific gravity of the electrolyte in each cell with a
hydrometer.
2. If the electrolyte temperature is different from the one that the
hydrometer calibrated, correct the specific gravity
measurement. Use the formula below in
(Reference)
.
3. If the specific gravity is less than 1.215 (after it is corrected for
temperature), charge or replace the battery.
4. If the specific gravity is different between 2 cells by more than
0.05, replace the battery.
NOTE
• Hold the hydrometer tube vertically but do not remove it
from the electrolyte.
• Do not put too much electrolyte into the tube.
• Let the float move freely and hold the hydrometer at eye
level.
• You must read the hydrometer at the highest electrolyte
level.
(Reference)
• The specific gravity changes with temperature.
To be accurate, the specific gravity
decreases by 0.0007 when temperature increases by 1 °C
(decreases by 0.0004 when temperature increases by 1 °F),
increases by 0.0007 when temperature decreases by 1 °C
(increases by 0.0004 when temperature decreases by 1 °F).
Thus, if you refer to 20 °C (68 °F), correct the specific gravity
reading by the formula below :
–
Specific gravity at 20 °C = Measured value + 0.0007 ×
(electrolyte temperature
−
20 °C)
–
Specific gravity at 68 °F = Measured value + 0.0004 ×
(electrolyte temperature
−
68 °F)
At an electrolyte temperature of 20 °C (68 °F)
M00000003GEG0034US1
[10] CHECK POINTS FOR EVERY YEAR
Replacement of Air Cleaner Element
1. Remove used air cleaner element.
2. Replace it with a new one.
NOTE
• The air cleaner uses a dry element. Do not apply oil to it.
• Do not operate the engine without the filter element.
M00000003GEG0035US1
Specific Gravity
State of Charge
1.260 Sp. Gr.
100 % Charged
1.230 Sp. Gr.
75 % Charged
1.200 Sp. Gr.
50 % Charged
1.170 Sp. Gr.
25 % Charged
1.140 Sp. Gr.
Very Little Useful Capacity
1.110 Sp. Gr.
Discharged
(a) Good
(b) Bad
(c) Bad
KiSC issued 06, 2009 A