© by N&W GLOBAL VENDING S.p.A.
39
03 - 2011 3685 00
STATISTICS
The data related to the operation of the machine are
stored both in total counters and in relative counters,
which can be reset without losing the total data.
E
lEcTroNic
couNTEr
An electronic counter memorizes in an aggregate mode
all the items dispensed from the last reset.
D
isplay
ElEcTroNic
couNTEr
Displays the number of items dispensed since the last
reset.
r
EsET
ElEcTroNic
couNTEr
Resets the electronic counter.
D
isplay
NumbEr
of
sTrokEs
aT
sTarT
-
up
Enables the display of the total number of items dis-
pensed since the last reset, during the machine start-up
phase.
Eva DTs
EVA DTS communication protocol (European Vending
Associations Data Transfer System) foresees two codes
for identifying the machine and recognising the data
transfer terminal:
STATISTICS
EVA DTS
DEX - UCS
DDCMP ENHANCED
ENGINEER> X.X
c
ommuNicaTioN
proTocol
From this function it is possible to decide which commu-
nication protocol to use for the communication with the
data acquisition device.
The available communication protocols are:
DDcmp
ENHaNcED
with the following configurable parameters:
-
Pass code
: this is an alphanumeric code (0-9; A-F) of
four digits which must be equal to the one of the data
transfer terminal for permitting its identification.
Default setting: 0000
-
Security code
: this is an alphanumeric code for mutual
recognition between machine and EVA DTS terminal.
Default setting: 0000
-
End of transmission
: if enabled, it is capable of rec-
ognising the end of transmission signal which is sent
with the last packet and of interrupting the data trans-
mission.
DEx
/
ucs
for this protocol there are no configurable parameters:
D
aTa
TraNsmissioN
This function allows you to select which communica-
tion interface to use for data transmission. The available
interfaces are:
-“RS232” and “IrDA”: for the communication with serial
or infrared data acquisition devices.
-“ALWAYS EVA DTS” for communications with data
acquisition and transmission devices (telemetry).
E
vaDTs
TypE
This function allows you to select the mode in which
to manage the speed of communication with the data
acquisition devices:
-“ENHANCED”, the communication speed is automati-
cally adjusted to the maximum speed of the slowest
device.
-“FIXED”, the communication speed is fixed to the
speed set with the Baudrate function
bauDraTE
(
TraNsmissioN
spEED
)
This allows you to choose the communication speed of
transmissions (only if “EVA DTS type” is set with “fixed”).
Default setting: 2400bps.
c
oNNEcTioN
By activating this function, the machine waits for the con-
nection with a data acquisition device EVA DTS.
E
rasiNg
DaTa
The statistics can be reset, for the relative counters, in
a global mode (all types of data) or in a selective mode,
for:
-selections
-discounts-overpays
-faults
-coin mech data
-By pressing the confirmation key
�
the flashing confir-
mation request “Confirm?” is displayed.
By pressing the confirmation key
�
the message “Ex-
ecution” is displayed for a few seconds and the statistics
are reset.