© by N&W GLOBAL VENDING S.p.A.
26
03 - 2011 3685 00
ENGINEER MENU
Below is an explanation of the main software functions
which manage the operation of the machine, grouped
by logic of use and not necessarily in the order in which
they are displayed in the menu.
The software version can be updated using the appropri-
ate systems (PC, Giga, UpKey, etc.)
For more information and details please refer to the
doses table supplied with the machine, taking into ac-
count the software version of the machine.
By pressing the key
�
from the “Loader” mode, the ma-
chine goes into “Engineer menu” mode.
The display shows the first item of the “Engineer” menu
with the available operations.
The last row of the display contains the menu and the
number, which allow you to identify the current level.
ENGINEER
PAYMENT SYSTEMS
PRICES
DOSES
D.A. CONFIGURATION
TEST
STATISTICS
ENGINEER> X.X
-By pressing the confirmation key
�
you can access the
menu.
-By pressing the exit key
�
you go back to the previous
menu.
-The keys
�
and
�
allow you to navigate through the
items of the menu:
Notes:
If you want to go back to the Loader mode, press the key
�
from any first level function.
PAYMENT SYSTEMS
This function is active only if the machine has a
payment module.
It is possible to decide which of the protocols for the
expected payment systems to enable and manage the
related functions.
PAYMENT SYSTEMS
Coin mech type
Validator
ENGINEER> X.X
The communication protocols for the expected payment
systems are:
-Validators
-Executive
-BDV
-MDB
Some of the parameters, which are common among
several payment systems, keep the set value even if the
system type is changed.
If necessary, they can be modified from the menus of the
payment systems.
v
aliDaTor
i
mmEDiaTE
cHaNgE
Usually the amount related to a selection is cashed in
after the machine sends the signal “Selection made”.
By enabling this function, which is disabled by default,
the payment signal is sent at the beginning of the dis-
pensing.
Setting this parameter is compulsory.
D
Ecimal
poiNT
Pressing the confirmation key
�
displays the position of
the decimal point, in particular:
0
decimal point disabled
1
XXX.X (one decimal place)
2
XX.XX (two decimal places)
3
X.XXX (three decimal places)
By pressing the confirmation key
�
, these values flash
and they can be modified.
l
iNE
/
valuE
associaTioN
When the display is positioned on the function “LINE-
VALUE ASSOC.” (line programming) of the “program-
ming” menu, it is possible to vary the value of the 6 coins
lines, from A to F, of the validator.
o
vErpay
It is possible to decide whether to cash in or leave the
user any credit exceeding the amount of the selection.
Содержание Krea