background image

NANAWALL WD66 OWNER’S MANUAL

17 

See Finishing Recommendations in the Owner’s 
Manual of the wood systems.

9.  All hardware, hinges and handles should be 

periodically cleaned with a soft cloth and mild 
cleanser. Excessive abrasive rubbing should be 
avoided. Please note that oil rubbed brass is a finish 
that will develop its own unique patina over time.

10.  About every six months, apply lubricant to all the 

hinges and Teflon spray to the running carriages and 
guiding trolleys. 

SOME SPECIFIC SUGGESTED MAINTENANCE 
FOR COASTAL SALT WATER AND OTHER 
EXTREME ENVIRONMENTS:

Please note that the environment within one mile of a 
sea coast can be extremely corrosive. Products installed 
in this environment will typically deteriorate sooner than 
products installed in a less severe environment.

1.  Open and close completely a unit at least once a 

week and inspect all surfaces.

a.  Salt and other corrosive or abrasive materials 

such as sand must not be allowed to build up on 
any surfaces, including all hardware and sill.

b.  The sill and head jamb tracks should be free from 

all dirt and debris.

c.  There should be no standing water in the track 

in the sill.

d.  All hardware should be intact and operating 

properly.

2.  All surfaces must be cleaned with a mild detergent 

soap and fresh water at least every month and more 
frequently if necessary.

a.  After washing, the surface should be rinsed 

thoroughly with clean water and allowed to dry.

b.  For cleaning, do not use abrasive household 

cleaners or materials like steel wool or hard 
brushes that can wear and harm finishes.

c.  Any glass cleaner used should not be allowed to 

run down on any other surface.

3.  Any breaches in the paint coating, such as scratches, 

chips or areas of abrasion, must be repaired 
immediately.

4.  Every 3 months, thoroughly clean and dry all upper 

and lower rollers and all hinges. Liberally apply 
lubricant such as Teflon spray (no grease) on the 
wheels and bearings of the rollers. Oil all hinges 
including the hinge pin with light weight lubricating 
oil or Teflon spray.

5.  As with any painted surface exposed to corrosive 

environments, every 6 months apply a wax to the 
outside of the painted panel and painted track.  If the 
system includes corner connections make sure the 
wax penetrates the connection joints.

Содержание WD66

Страница 1: ...6 Standard Wood Framed Folding System This manual is to be used by the installer for installation and is to be kept by the Owner for reference Replacement parts can be ordered directly through NanaWal...

Страница 2: ...However not included are screws bolts shims etc to anchor the unit to the rough opening The frame is shipped knocked down and needs to be assembled Panels are pre assembled with or without glass read...

Страница 3: ...e frame height of the unit ordered is measured from the bottom of the sill and not from the finished floor Allowance must be made in height for the portion of the sill that is below the measured openi...

Страница 4: ...protection any exterior folding system should be installed under an overhang or with other similar protection 7 For better performance it is recommended that all dead loads such as upper levels roof...

Страница 5: ...stomer s specific application requirements can be evaluated Your local paint professional should know of suitable finish systems that give satisfactory results in your region It is highly recommended...

Страница 6: ...stainless steel insert for the sill of floor supported WD66 u are in the correct place Illustration A1 Step A3 For top hung WD66 o L R with unhinged pairs of panels not connected to a side jamb see St...

Страница 7: ...c surrounding conditions must be properly designed and provided by others Drawings not to scale Details shown are subject to change without notice INWARD OPENING DETAILS OUTWARD OPENING DETAILS TOP HU...

Страница 8: ...s or other equivalent anchorage devices depending on the adjacent substrate material and construction Make sure they are corrosion resistant Anchorage devices should penetrate or hold sufficiently INW...

Страница 9: ...of 3 200 psi use 3 16 diameter ITW Tapcons concrete screws with 1 1 4 min embedment For masonry use 1 4 diameter ITW Tapcons masonry screws with 1 1 4 embedment Standard installation into light gage s...

Страница 10: ...nd free of any debris especially cuttings from drilled holes See Illustration A3 B PANELS AND FOLDING HARDWARE INSTALLATION IMPORTANT Look for glass stops to determine the interior side of a panel Ste...

Страница 11: ...t secures the assembly See also Illustration B3 Step B6 Attach the next panel to this folding pair by demounting the long screw of the running carriage that way that the hinge part of the next panel c...

Страница 12: ...panel If it is slightly lower not more than 1 16 it is okay Then along the entire width of the opening check the spacing between the sill and each panel which should be about 3 8 along the entire leng...

Страница 13: ...ep C11 Finish any waterproofing flashing trim and sealant needed around the perimeter of the opening Important Make sure any weep holes in the sill are not blocked Step C12 To prevent uncontrolled mov...

Страница 14: ...curity and weather resistance When closed please engage all locking mechanisms fully The correct sequence of opening and closing of panels is dependent on the configuration ordered Panels must be open...

Страница 15: ...side or a thumb turn on the inside Unlock and disengaging the locking points Unlock the lock with key or thumb turn By operating the door handle downwards the locking points at the top and the bottom...

Страница 16: ...al loading and forced entry 5 Periodically inspect the sealant caulking on the exterior perimeter of the unit It is extremely important that the sealant caulking remains intact and in good condition T...

Страница 17: ...jamb tracks should be free from all dirt and debris c There should be no standing water in the track in the sill d All hardware should be intact and operating properly 2 All surfaces must be cleaned w...

Страница 18: ...Insulating Glass shall meet the requirements of ASTM E 774 Class A B or C Although glass installation with the dry glazing system is relatively straight forward it is recommended that an experienced...

Страница 19: ...pry bar at the lower corner below the upper setting block These setting blocks should all fit snugly but should not be forced Adjust the thickness of the glass setting blocks such that the panel is sl...

Страница 20: ...ls have to be braced correctly for proper operation DIAGRAM 1 Setting blocks for tension Setting blocks to keep distance B r a c i n g D i r e c t i o n B r a c i n g D i r e c t i o n B r a c i n g D...

Страница 21: ...must be provided 3 Inward opening details are shown on this drawing Outward opening panels require the same installation fasteners at the same spacings 4 Installation fasteners shown in the raised si...

Страница 22: ...antial cracking chipping or peeling due to the deterioration of the finish exclusive of mechanical damage 2 chalking in excess of a numerical rating of 8 as per ASTM D 659 or 3 fading or color changes...

Страница 23: ...e of the affected product in full satisfaction of its obligations Wood Wood components must be properly finished on all sides promptly after receipt of unit before installation of unit and prior to ex...

Страница 24: ...Product selection application storage handling modification or waterproofing Movement of surrounding substrates including deflection of the header of more than or any other stresses on product Instal...

Страница 25: ...faces Acts of God falling objects fire accidents external forces or other conditions beyond NanaWall s control Gas fill or retention levels in insulated glass units Field testing of Product Performanc...

Страница 26: ...___________________________________ Project Address if different from above _____________________________________________________________ INSTALLATION Installer Name _______________________________ Ad...

Отзывы: