Some General Considerations on all Projects:

1.

It is important that the product is installed correctly.
A poorly installed unit will not function properly.
This will cause more abnormal force or stress on
the components and will lead to premature failure.
When operating the unit, the panels should generally
be able to be moved easily by one person (except
when there are very large panels or when there are
more than 6 panels folding to one side). All locking
points should engage smoothly. There should be no
rubbing on the floor and no binding. When the unit is
closed, the reveal between panels and head jamb and
between panels and sill should be consistent. There
should be no daylight seen from the inside. Please
have all problems corrected as soon as possible by a
qualified technician.

2. From time to time, due to building movement or

settlement, a unit may need to be adjusted by a
qualified technician to compensate for any building
change.

3. It is important that a unit is operated properly.

Locking points should be gently opened and closed
and not forced. Panels should be opened and
closed in the proper manner and sequence. See the
Operation section for proper operation.

4. Periodically check for worn or damaged components

and replace as soon as possible. A unit with
nonworking components will subject the other
components to increased stress and lead to
premature failure. A unit with worn or damaged
components will compromise the performance level
expected for air and water infiltration, structural
loading and forced entry.

5. Periodically, inspect the sealant/caulking on the

exterior perimeter of the unit. It is extremely
important that the sealant/caulking remains intact
and in good condition. Trim off any old, loose caulking
and seal any gaps with a good quality caulk.

6. Check that all weep holes are clean and clear of any

obstructions. Remove debris and other foreign bodies
which have dropped into the tracks in the head jamb
and sill immediately to prevent damaging the running
carriages and guide trolleys. Clean all components as
needed.

Check gaskets for proper seating and condition.
Remove dust and any deposits from these gaskets.

7.

The finished aluminum or wood surface needs
periodic cleaning and maintenance. Its appearance
may be marred by harsh chemicals, abuse or neglect.
Frequency of cleaning depends on exposure and
needs. For aluminum surfaces, generally warm
soapy water should be sufficient. Stubborn stains
and deposits may be removed with mineral spirits.
For wood surfaces, superficial surface dirt can be
removed by washing with water and a soft-bristled,
long-handled brush. Heavier accumulations can
be removed with a mild solution of household
detergent. For all surfaces, aggressive alkaline or
acid cleaners should not be used. Excessive abrasive
rubbing should be avoided. Sealants and weather
stripping may be affected by strong organic solvents.
Superficial damage to the aluminum surface must be
touched up immediately with proper touch up paint.

8. If it is a wood product, the surface should be visually

inspected every six months or earlier, depending
on the exposure of the NanaWall unit. Periodically
repaint or restain the wood as needed. Exposure
to the environment will break down the finish and
compromise its protective features if not refinished.

Содержание WD66

Страница 1: ...6 Standard Wood Framed Folding System This manual is to be used by the installer for installation and is to be kept by the Owner for reference Replacement parts can be ordered directly through NanaWal...

Страница 2: ...However not included are screws bolts shims etc to anchor the unit to the rough opening The frame is shipped knocked down and needs to be assembled Panels are pre assembled with or without glass read...

Страница 3: ...e frame height of the unit ordered is measured from the bottom of the sill and not from the finished floor Allowance must be made in height for the portion of the sill that is below the measured openi...

Страница 4: ...protection any exterior folding system should be installed under an overhang or with other similar protection 7 For better performance it is recommended that all dead loads such as upper levels roof...

Страница 5: ...stomer s specific application requirements can be evaluated Your local paint professional should know of suitable finish systems that give satisfactory results in your region It is highly recommended...

Страница 6: ...stainless steel insert for the sill of floor supported WD66 u are in the correct place Illustration A1 Step A3 For top hung WD66 o L R with unhinged pairs of panels not connected to a side jamb see St...

Страница 7: ...c surrounding conditions must be properly designed and provided by others Drawings not to scale Details shown are subject to change without notice INWARD OPENING DETAILS OUTWARD OPENING DETAILS TOP HU...

Страница 8: ...s or other equivalent anchorage devices depending on the adjacent substrate material and construction Make sure they are corrosion resistant Anchorage devices should penetrate or hold sufficiently INW...

Страница 9: ...of 3 200 psi use 3 16 diameter ITW Tapcons concrete screws with 1 1 4 min embedment For masonry use 1 4 diameter ITW Tapcons masonry screws with 1 1 4 embedment Standard installation into light gage s...

Страница 10: ...nd free of any debris especially cuttings from drilled holes See Illustration A3 B PANELS AND FOLDING HARDWARE INSTALLATION IMPORTANT Look for glass stops to determine the interior side of a panel Ste...

Страница 11: ...t secures the assembly See also Illustration B3 Step B6 Attach the next panel to this folding pair by demounting the long screw of the running carriage that way that the hinge part of the next panel c...

Страница 12: ...panel If it is slightly lower not more than 1 16 it is okay Then along the entire width of the opening check the spacing between the sill and each panel which should be about 3 8 along the entire leng...

Страница 13: ...ep C11 Finish any waterproofing flashing trim and sealant needed around the perimeter of the opening Important Make sure any weep holes in the sill are not blocked Step C12 To prevent uncontrolled mov...

Страница 14: ...curity and weather resistance When closed please engage all locking mechanisms fully The correct sequence of opening and closing of panels is dependent on the configuration ordered Panels must be open...

Страница 15: ...side or a thumb turn on the inside Unlock and disengaging the locking points Unlock the lock with key or thumb turn By operating the door handle downwards the locking points at the top and the bottom...

Страница 16: ...al loading and forced entry 5 Periodically inspect the sealant caulking on the exterior perimeter of the unit It is extremely important that the sealant caulking remains intact and in good condition T...

Страница 17: ...jamb tracks should be free from all dirt and debris c There should be no standing water in the track in the sill d All hardware should be intact and operating properly 2 All surfaces must be cleaned w...

Страница 18: ...Insulating Glass shall meet the requirements of ASTM E 774 Class A B or C Although glass installation with the dry glazing system is relatively straight forward it is recommended that an experienced...

Страница 19: ...pry bar at the lower corner below the upper setting block These setting blocks should all fit snugly but should not be forced Adjust the thickness of the glass setting blocks such that the panel is sl...

Страница 20: ...ls have to be braced correctly for proper operation DIAGRAM 1 Setting blocks for tension Setting blocks to keep distance B r a c i n g D i r e c t i o n B r a c i n g D i r e c t i o n B r a c i n g D...

Страница 21: ...must be provided 3 Inward opening details are shown on this drawing Outward opening panels require the same installation fasteners at the same spacings 4 Installation fasteners shown in the raised si...

Страница 22: ...antial cracking chipping or peeling due to the deterioration of the finish exclusive of mechanical damage 2 chalking in excess of a numerical rating of 8 as per ASTM D 659 or 3 fading or color changes...

Страница 23: ...e of the affected product in full satisfaction of its obligations Wood Wood components must be properly finished on all sides promptly after receipt of unit before installation of unit and prior to ex...

Страница 24: ...Product selection application storage handling modification or waterproofing Movement of surrounding substrates including deflection of the header of more than or any other stresses on product Instal...

Страница 25: ...faces Acts of God falling objects fire accidents external forces or other conditions beyond NanaWall s control Gas fill or retention levels in insulated glass units Field testing of Product Performanc...

Страница 26: ...___________________________________ Project Address if different from above _____________________________________________________________ INSTALLATION Installer Name _______________________________ Ad...

Отзывы: