4. NKD1 SYSTEM INSTALLATION
4.2 Control Unit Installation
•
The NKD1 Control Unit has an Ingress Protection Rating of IP23 enabling it to be installed outdoors.
Regulations require that the Control Unit shall be installed outside the pool zone. The Control Unit
shall be installed according to AS/NZS 3000 wiring rules.
•
The Control Unit should be installed in a well ventilated position ideally away from sunlight and
rain to prolong life and at least 1m above ground to prevent run off water entry.
•
Ensure that the Control Unit is not stored near chemicals, fertilisers or in a closed unventilated
shed with similar products as the fumes will cause excessive corrosion and damage to the internals
of the Control Unit and may void warranty.
•
When mounting the Control Unit on a post it is recommended to install a at panel at least the
same size to act as a waterproof backing plate.
•
Mount the Control Unit with the Wall Mounting Bracket, Green Plugs and Screws provided.
The Control Unit should be mounted no further than 1.5 metres from the Housing for ease of
operation.
4.1 Installation Diagram
OXI & ION CELL
FILTER
PUMP
POWER
CONTROL UNIT
(Ensure good ven la on)
RETURN
TO POOL
FROM
SKIMMER BOX
WARNING:
DO NOT
plug in if carton has been wet.
www.naked-pools.com
8