background image

13. WARRANTY

THIS EQUIPMENT HAS BEEN MANUFACTURED AND TESTED TO THE HIGHEST STANDARD AND 

ACCORDINGLY CARRIES THE FOLLOWING WARRANTY.

The NKD1 Fresh Water System Control Unit will be repaired at no charge for a period of 36 Months from the 
date of purchase should it be found, after examination, that the failure has been caused by faulty 
workmanship or materials. This is a back to base warranty. The Electrolytic Cell carries a 3 year warranty. 
*The warranty applicable to commercial application is limited to 12 months from the date of installation 
unless a commercial model is purchased then this is 24 months. 

13.1

Adverse operating conditions beyond the control of the manufacturer such as improper voltage or water 
pressure, excessive ambient temperature or any condition that adversely affects the performance of the 
equipment will render this warranty null and void.

13.2

Defective equipment must be returned to the manufacturer or dealer as soon as the purchaser becomes 
aware of the defect and all transport must be prepaid. Neither the manufacturer nor the dealer shall be 
responsible for any goods damaged in transit.

13.3

If after examination the equipment is found to be defective it will be repaired or replaced free of charge 
(other than transport costs which will be borne by the purchaser). However, if upon inspection of the 
equipment it is found that the terms of this warranty are not satis ed, then the usual charges of the 
manufacturer for repair or replacement will be made.

13.4

Any liability of the manufacturer pursuant to the Trade Practices Act 1974, as amended for a breach of a 
condition or warranty shall be limited to replacing or acquiring the equipment (or part thereof ) where the 
same has been supplied.

13.5

The maximum liability incurred by the manufacturer shall not in any case exceed the contract price for the 
equipment or the product parts or components thereof claimed to be defective. Further, the manufacturer 
shall not be liable for any loss, damage or delay directly or indirectly caused by any malfunction of or defect 
of or failure of the equipment other than as expressly provided in this warranty.

13.6

Products sold by the manufacturer are designed for use with swimming pool water balanced in accordance 
with the Langelier Saturation Index with a pH range of 6.8-7.8. Copper levels should not exceed 0.5ppm and 
the TDS level should not exceed 1200ppm.

13.7

The manufacturer will not be held liable for damage caused by, but not limited to, corrosion, scaling or 
stress.

13.8

The Warranty is void under the following circumstances:

• 

Installation is carried out incorrectly by any person other than a person authorised by us to do so.

• 

The Control Unit or Cell Electrode is serviced by any person other than a person authorised by us to do so.

• 

Correct TDS levels are not maintained at all times.

• 

The Control Unit is not protected from the elements.

• 

The Control Unit is not operated in a position/area with good ventilation.

• 

Water has been allowed to enter the Control Unit.

• 

Run in a commercial installation (these have a 1 year warranty on Control Unit and Cell Electrode unless a   

  commercial application is granted then this is 24 months).

• 

Insect infestation or penetration by dust, sand or other foreign particles inside the Control Unit.

• 

Damage beyond our control.

• 

Equipment that has been misused, neglected, damaged, repaired without authorisation or altered in any way.

• 

This warranty is applicable to workmanship and materials only.

• 

This warranty is not transferable under any circumstance.

• 

This system is for use in domestic swimming pools only. Used in commercial applications voids the

  Warranty unless a commercial application has been granted.

www.naked-pools.com

33

Содержание NKD1

Страница 1: ...Installation Operating Guide...

Страница 2: ...8 4 2 Control Unit Installation 8 4 3 OXI Cell Housing Installation 9 4 4 ION Installation 9 5 STARTING YOUR NKD1 FRESH WATER SYSTEM 10 5 1 Switching on the Unit 10 5 2 Start Up Clock Set 10 5 3 Mine...

Страница 3: ...ode 20 7 14 ION Setting 20 8 WATER CHEMISTRY 21 8 1 Copper 21 8 2 TDS Levels 22 8 3 pH 22 8 4 Total Alkalinity 22 8 5 Calcium Hardness 23 9 SYSTEM MAINTENANCE 24 9 1 Inspecting and Cleaning the OXI Ce...

Страница 4: ...ding to AS NZS 3000 wiring rules It shall be installed outside the pool zone Please contact Naked Pools on 1300 625 331 for further assistance To reduce the risk of injury do not permit young children...

Страница 5: ...f water Smart self cleaning technology allows the polarity of the OXI Cell plates to change direction every 4 16hrs depending on your setting Reversing times can be changed see 7 3 CELL CLEANING The c...

Страница 6: ...HACKSAW NO 2 PHILIPS HEAD SCREWDRIVER PVC PRIMER AND GLUE A B 2X Green Wall Plugs with Screws The Installation Operating Manual 2X50 40 Redusing Bushes CONTROL UNIT OXIDISER IONISER HOUSING WITH UNIO...

Страница 7: ...llow end of the pool and allowed to dissolve Do not let the salt settle on the oor of the pool as this may cause damage to the surface Use your pool brush to mix the salt into the water Running the pu...

Страница 8: ...ot stored near chemicals fertilisers or in a closed unventilated shed with similar products as the fumes will cause excessive corrosion and damage to the internals of the Control Unit and may void war...

Страница 9: ...gas trap that acts as a safety device Installation in any other way may cause explosion injury or death if the installer does not allow for gas removal A venturi pipe is installed moulded within the...

Страница 10: ...al used in the pool Pressing or will change it from SALT to MINERAL MIX The reason for this is because a higher salt reading TDS value is required for MINERALS to be as conductive as SALT Pressing OK...

Страница 11: ...y to ensure the copper levels are correct in the water based on the pool size entered in the previous screen 5 6 Default Display Screen DEFAULT DISPLAY SCREEN DDS displays the screen to the right This...

Страница 12: ...N MENU allows you to enter all MENU s including those available with shortcut buttons on the control panel Pressing takes you to the last menu and using the or OK enters the rst 3 menus Pressing retur...

Страница 13: ...ht Press OK to enter POWER MODE Pressing OK enters the display shown to the right and pressing the or allows you to adjust the POWER MODE setting from AUTO to OFF to ON Pressing OK saves the required...

Страница 14: ...and decreases the time Pressing OK accepts the selected hour HH Pressing exits you to the DDS screen MM digits ash and pressing increases the time and decreases the time Pressing OK accepts the select...

Страница 15: ...IME HH HH digits ash and pressing increases the time and decreases the time Pressing OK accepts the selected hour HH Pressing returns you to the previous display TIMER 1 OFF TIME MM MM digits ash and...

Страница 16: ...i port valve to the backwash position ensure the handle locks in place and once ready press OK to enter the RINSE MODE cycle Pressing or BACKWASH allows you to exit and this takes you to BACKWASH COMP...

Страница 17: ...tting by increments of 10 from 0 to 90 Once your desired set point is entered pressing OK will return to the DDS screen and the output will display at the lowered set point 50 or di erent if you set i...

Страница 18: ...dge and keep the OXI plates clean Please note occasional cleaning of the plates may be necessary The factory setting is every 10 hours and this can be adjusted from as low as 4 hours for high calcium...

Страница 19: ...lling to PUMP SETTING Menu 9 The default setting is 3 minutes and pressing or allows you to adjust the time the pump is turned o for Pressing OK saves the required protection time You can also select...

Страница 20: ...3 seconds the direction will change to REV At the same time you will also be displayed the current reading in XXX Xamps Pressing returns you to the previous screen The TDS TEST measurement is meant to...

Страница 21: ...not use Stabilizer Cyanuric Acid Do not use Bromine compounds Do not use Aluminium based or any other occulants Do not use Soda Ash Sodium Carbonate Do not use Granular Chlorine Do not use forms of Z...

Страница 22: ...e your pool brush to mix the salt minerals into the water Running the pump will mix the water and help the salt minerals to dissolve 8 4 Total Alkalinity Measurement Interval Every 4 6 weeks 8 2 TDS L...

Страница 23: ...er does not become too corrosive or end up scaling the surface of your pool These are symptoms of swimming pool water that is unbalanced THE MOST IMPORTANT NOTICE AND WARNING Only add chemicals in the...

Страница 24: ...f your system All electrodes must be cleaned before scale calcium builds up to the point where the electrode gaps in the OXI Cell become bridged If the OXI Cell has excessive calcium deposit this may...

Страница 25: ...eplace with new NKD ION Rods and repeat the process ensuring that the O ring is clean greased and properly seated and the Locking Ring is hand tight and secure Turn on the wall outlet switch and the p...

Страница 26: ...Low water ow Water does not cover the water sensor Low speed pump not supplying su cient water to cell housing Increase the speed of the pump until housing is lled Build up of calcium on the Cell pla...

Страница 27: ...does not work If the FAULT LED is ON then refer to above If only LCD DISPLAY is ON but nothing works call for service 1800 NAKED1 625 331 Sign of melting or burning of the OXI or ION Connector Plug P...

Страница 28: ...ngs Make sure POWER MODE is set to AUTO Refer to Timer Setting in this manual sec 6 51 10 17 TDS level is to low Check TDS guide sec 7 10 8 2 pH is too high Check pH guide sec 8 3 Cell at the ends of...

Страница 29: ...TICS AND PART NUMBERS NAKED NKD1 FRESHWATER SYSTEM 1 18 25 36 19 20 17 12 13 24 23 5 6 4 3 2 7 27 21 9 10 11 22 16 26 14 15 8 28 If in doubt please visit the website or call 1800 Naked1 www naked pool...

Страница 30: ...Relief Bush Screw M3x12 Stainless Steel 304 Fan NKD1 Fan Support Plate BLACK Ioniser Plug SL 13 Female End Complete with 2 x SL 09 Wire Looms N00693 N00870 N00367 N00842 N00022 1 N00011 NKD1 LCD Displ...

Страница 31: ...ble cover cap brassware washers resin lled 64 NKD1 Oxidiser Electrode Cap Locking Ring O Ring NKD1 Oxidiser Electrode EPDM rubber 63 62 Electrode Housing 3 Way Smokey Naked Description 61 NKD1 Oxidise...

Страница 32: ...G SALT TEST YOUR POOL WATER FOR THE TOTAL TDS LEVELS RECOMMENDED TDS LEVELS FOR NAKED POOLS FRESH WATER SYSTEMS 800 1000PPM NEVER ADD SALT DIRECTLY TO THE SKIMMER BOX This high concentration of salt w...

Страница 33: ...ability incurred by the manufacturer shall not in any case exceed the contract price for the equipment or the product parts or components thereof claimed to be defective Further the manufacturer shall...

Страница 34: ...ld the guide be used as a substitute for such professionals No representations or warranities are made that the content advice and recommendations in this guide are current free from errors or omissio...

Страница 35: ...15 NOTES If in doubt please visit the website or call 1800 Naked1 www naked pools com 35...

Страница 36: ...swimming as nature intended P 1800 NAKED1 625 331 E warranty naked pools com W www naked pools com...

Отзывы: