10. SYSTEM TROUBLESHOOTING
www.naked-pools.com
28
Fault
Indication
Potential Cause
Remedy
The Cell could be damaged or at
the end of its life
Damaged coating will reduce cell
life and reduce output
If all conditions are correct then
Cell could be at the end of its life
Level low in one direction but OK
in the other
Cell may need cleaning (sec. 9.1)
or the Cell may have run its life in
one direction
Continuous build up of calcium
See this troubleshooting sec 9.10
Control Unit only works in one
direction
No output in one direction
Faulty recti ers, transformer or
PCB
Return unit for service call 1800
NAKED1 (625 331)
10.16
Low or No OXI Output
Unit not working correctly
Go through Troubleshooting from
9.1
10.20
Unit not set correctly
Basic settings such as Output
Control and Timer running hours
need to be checked
Go through all settings in sec. 5, 6
& 7 and balance water accordingly
Timer is not functioning properly
in AUTO
Incorrect settings
Make sure POWER/MODE is set to
AUTO. Refer to Timer Setting in
this manual (sec. 6.51)
10.17
TDS level is to low
Check TDS guide (
sec 7.10/8.2
)
pH is too high
Check pH guide (sec. 8.3)
Cell at the ends of its life
If full output is not reached then it
could be a failing Cell
Timer loses time when mains
power removed
Battery life expired
Replace Battery - return for service
10.21
Pool pump outlet not functioning
properly or pump always on
Pump not plugged into the base
of system
Check that pump is plugged into
the bottom of the CONTROL UNIT
and not directly in to the wall
outlet
Make sure you are set in AUTO
mode and not MANUAL for
normal running
10.18
Cell not cleaning, excessive
calcium build up on Cell or
Control Unit not changing
direction
Excessively high calcium, change
of direction time set too high or
faulty PCB
1. See Calcium Hardness test (sec
8.5) and adjust water accordingly
2. Change the Cell Cleaning times
(sec. 7.3)
3. Manually try changing direction
by holding both [<] and [>]
buttons in for 3 sec (you must be
in the default display screen for
this to work). Failure for this to
work could indicate a faulty PCB -
return for service
10.19