(Revised 4-9-2013)   NT24k Managed Industrial Ethernet Switch User Manual & Installation Guide  Page 20 of 132 

 
 

 
 
APPLYING POWER AND FAULT CONNECTIONS (Back View) 
 

All NT24k can operate with one power supply, either AC or DC. The Rack Mount NT24k can accept up to 
two power supply units. Each power supply can be AC or DC. Each low voltage DC Power supply includes 
redundancy (two DC supplies). 
 

The example below is shown from the back and includes a AC Power supply on the left and a DC 
power supply on the right, looking from the back: 

 

 
 
NT24k with DC Power Supply Installed: 

 

 

 

Unscrew & Remove the DC Voltage Input 
Plug from the Power Input Header 

 

Install the DC Power Cables into the Plug 
(observing polarity). 

 

Plug the Voltage Input Plug back into the 
Power Input Header. 

 

Tightening torque for the terminal block 
power plug is 

0.5 Nm/0.368 Pound Foot. 

 

Verify the Power LED stays ON. 

Notes:

   

 

When a DC Power supply is installed, only one power supply must be connected to power for 
minimal operation.  For redundant power operation, V

1

 and V

2

 inputs must be connected to separate 

DC Voltage sources.  This device will draw current from both sources simultaneously.  Use 16-28 
gauge wire when connecting to the power supply. 

 

Recommended 24V DC Power Supplies, similar to: N-Tron’s P/N 

NTPS-24-1.5 

 

 

Input AC 115/230V 

 

Output DC 24-28V 

 

Output Current 1.5A @ 24V 

                               1.0A @ 28V 

 

Power 36W 

 

35 mm DIN-Rail Mountable 

 

Dimensions: 45X75X91 mm 

 

Содержание NT24k

Страница 1: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide...

Страница 2: ...ient 29 Web Software Configuration 31 Web Management 31 Web Management Product Information Page 32 Web Management Menu Structure 34 Configuration Page 35 Fault Page 36 File Transfer Page 38 System Pag...

Страница 3: ...Managed Industrial Ethernet Switch User Manual Installation Guide Page 3 of 132 SNMP Trap Stations 90 VLAN 92 Help Overview 97 Help Other 99 Appendix A XML Configuration File Factory Defaults 103 N TR...

Страница 4: ...al Ethernet Switch User Manual Installation Guide Page 4 of 132 NT24k Industrial Ethernet Switch Installation Guide The NT24k is available in three configurations and this document addresses all three...

Страница 5: ...igabit 16 for the NT24k DR16 ports and offer a wide range of connectivity options including 100Base Gigabit fiber optic and copper options in rugged Rack Mount or DIN rail enclosures Designed to handl...

Страница 6: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 6 of 132 NT24k Series Common Features Continued...

Страница 7: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 7 of 132 NT24k Series Common Features Continued...

Страница 8: ...Tron NT24k Rack Mounted Managed Industrial Ethernet Switch features connectivity for up to 24 Gigabit ports in a rugged 1U 19 rackmount enclosure Designed to handle the most demanding environments the...

Страница 9: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 9 of 132 NT24k Rack Mount Continued...

Страница 10: ...Managed Industrial Ethernet Switch User Manual Installation Guide Page 10 of 132 NT24k DR24 The NT24k DR24 Managed Industrial Ethernet Switch features connectivity for up to 24 Gigabit ports in a rug...

Страница 11: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 11 of 132 NT24k DR24 Continued...

Страница 12: ...naged Industrial Ethernet Switch User Manual Installation Guide Page 12 of 132 NT24k DR16 The N Tron NT24k DR16 Managed Industrial Ethernet Switch features connectivity for up to 16 Gigabit ports in a...

Страница 13: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 13 of 132 NT24k DR16 Continued...

Страница 14: ...the area is known to be non hazardous Connection or disconnection in an explosive atmosphere could result in an explosion NTCD CFG Configuration Device Ideal for saving or restoring switch configurat...

Страница 15: ...ncluding but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N Tron Corporation be liable for any incidental special indirect or conseque...

Страница 16: ...n com E MAIL N TRON_Support n tron com ENVIRONMENTAL SAFETY WARNING The unit may become very hot to the touch in high temperature environments so extreme caution should be exercised in handling when e...

Страница 17: ...Substitution of components may impair suitability for Class I Div 2 3 WARNING Explosion Hazard do not disconnect while circuit is live unless area is known to be non hazardous 4 WARNING Explosion Haza...

Страница 18: ...wer cable before removing any enclosure panel UNPACKING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only...

Страница 19: ...Module Required NTSFP TX Up to 16 NT24k SFP8 or NT24k DM8 NTSFP FX Up to 24 NT24k DM8 NTSFP SX Up to 24 NT24k SFP8 or NT24k DM8 NTSFP LX Up to 24 NT24k SFP8 or NT24k DM8 NOTE The RJ45 data ports have...

Страница 20: ...Plug from the Power Input Header Install the DC Power Cables into the Plug observing polarity Plug the Voltage Input Plug back into the Power Input Header Tightening torque for the terminal block pow...

Страница 21: ...Verify the Power LED stays ON When an AC Power supply is installed i e the AC option Use 12 24 gauge wire when connecting to the power supply NT24k Fault Pins The Fault pins on the back of the NT24k...

Страница 22: ...mpleted To connect any port to another device end node Switch or Repeater use a standard Category 5E straight through or crossover cable with a minimum length of one meter and a maximum length of 100...

Страница 23: ...isolated from chassis ground Therefore the user must not attempt to ground the switch to earth ground via the power supply In other N Tron switches it is common to use the V for the purpose of ground...

Страница 24: ...t5e cables manufactured to EIA 568A or 568B specifications are required for use with N Tron Switches In the event all Cat5e patch cable distances are small i e All Ethernet devices are located in the...

Страница 25: ...PPP Point to Point Protocol PPP allows any configuration and status that the browser does USB Cable Connect the USB port of your PC and the Switch using a standard USB cable You will require a cable...

Страница 26: ...ins silent for a random amount of time back off before attempting to transmit again Full Duplex Full duplex operation allows simultaneous communication between a pair of stations using point to point...

Страница 27: ...s forward unicast multicast and broadcast traffic only on LAN segments that serve the VLAN to which the traffic belongs A Default Virtual LAN VID 1 exists to which a port which is not a member of any...

Страница 28: ...her than forwarding them from the root bridge RSTP also sends out new BPDUs every hello time RSTP interoperates with older STP switches by falling back to STP when the older BPDUs are detected on brid...

Страница 29: ...sing all N Ring enabled switches in the ring a detailed ring map and fault location chart is also provided on the N Ring Manager s web browser N Ring status is also sent from the N Ring Manager to the...

Страница 30: ...e limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not instal...

Страница 31: ...oftware Configuration Web Management Enter the switch s IP address in any web browser and login to the web management feature of the NT24k The DHCP Client is enabled in factory defaults with 192 168 1...

Страница 32: ...ain home page the administrator can see some basic information like what firmware revision the switch is running The firmware can be upgraded at a later time in the field using http The Product Inform...

Страница 33: ...l Installation Guide Page 33 of 132 Version Build Date The firmware s build date Boot Loader The boot loader s software version Copyright The copyright URL The company s home page on the internet Swit...

Страница 34: ...ctions are described in the rest of this section The use of each of these pages is also described in this section On the left is the basic navigation Below that the Advanced folder can be opened to se...

Страница 35: ...tion device is installed the configuration will also be saved to the device Selecting the Restore button will discard all unsaved changes and load the most recently saved configuration settings Select...

Страница 36: ...ed Contact The fault is indicated by opening or closing the contact switch Power AC Left Indicates low voltage on the left AC power supply Power AC Right Indicates low voltage on the right AC power su...

Страница 37: ...the switch Looking from the front of the unit DC V1 and V2 are on the right side and DC V3 and V4 are on the left side If a low voltage DC power supply is installed these additional choices appear Po...

Страница 38: ...tors to backup their configurations to a server offsite in case they need to reload their custom configurations at a later time Administrators can for example update the firmware in the field without...

Страница 39: ...elected you can browse and select an image or configuration file to upgrade with Reference Appendix A XML Configuration File Factory Defaults NOTE THAT YOU MUST REBOOT THE SWITCH TO BEGIN RUNNING THE...

Страница 40: ...ch User Manual Installation Guide Page 40 of 132 File Transfer continued On Export Saved Configuration from switch pressing the Configuration Settings hyperlink brings up the Windows utilities to spec...

Страница 41: ...the device Gateway Contains the current Gateway of the device MAC Address MAC Address of the device System Up Time This parameter represents the total time count This time has elapsed since the switch...

Страница 42: ...t ID Option used by DHCP clients to specify their unique identifier The identifier may be the MAC address switch name or entered as a text string or hex characters Fallback IP Address Contains the con...

Страница 43: ...a username a password and the user s permissions user administrator User names may include all alphanumerical characters _ and and must be 3 to 15 characters long Passwords may include all printable c...

Страница 44: ...nued In order to remove a user simply click on the Remove button at the bottom of the page Following the Remove button on the above example the administrator can remove a user by entering in the user...

Страница 45: ...ble field displays the desired aging time for dynamically learned MAC addresses Inactive MAC addresses will be removed from the Hardware Address Entry Table after the aging time period has expired The...

Страница 46: ...age above the administrator must enter a valid Multicast Group Address and associate it with a port number or list on the switch Once the administrator clicks on the Add button the changes will take e...

Страница 47: ...ar on the main list and will show the associated ports that go along with that address Following the Remove button on the example above the administrator will be presented with a list of Multicast Gro...

Страница 48: ...lay a list of MAC addresses that are associated with each respective port number This can be used to statically assign a MAC address access to a single port on the switch Following the Add button on t...

Страница 49: ...ast Addresses Continued Once a staic MAC address has been added it will be displayed in a list on the main page under the Unicast Addresses tab Following the Remove button on the example above an admi...

Страница 50: ...ategory will display the IGMP basic configuration settings By default IGMP is enabled Following the Modify button the administrator will see a list of configurable fields for the IGMP configuration On...

Страница 51: ...2 IGMP Configuration Continued The IGMP Status pull down allows the user to enable or disable IGMP completely The Query Mode pull down allows the user to set query mode for Automatic the default On al...

Страница 52: ...ed The Router Mode pull down allows the user to choose router mode Auto allows for dynamically detected and manually set router ports Manual allows only for manually set router ports None allows no ro...

Страница 53: ...e Unused Groups is checked then unused IGMP Groups will be removed and traffic with those multicast addresses will be treated as normal multicast If unchecked then unused IGMP Groups are not removed a...

Страница 54: ...based on the Group IP and the port that it is associated with Total Number of Active IP Group Memberships Total Number of Active Group IP Memberships based on the dotted quad aaa bbb ccc ddd view and...

Страница 55: ...ps IGMP group data from egressing on the port unless a join to that specific IGMP group has come into the port IGMP controls Join Leave Query are still sent The factory default is that the Router Mult...

Страница 56: ...Page 56 of 132 IGMP RFilter Continued Modifying rfilter port settings After pressing Modify the administrator can select which ports to identify as RFilter ports or choose all ports The administrator...

Страница 57: ...net Switch User Manual Installation Guide Page 57 of 132 IGMP Routers The Routers tab under the IGMP category will display a list of Auto detected Router IPs and the port numbers that they are associa...

Страница 58: ...ot have RSTP enabled on the N_Ring ports N Ring Manager will disable RSTP on the N Ring ports if necessary Other ports may have RSTP enabled 5 RSTP N Ring are different modes and cannot share links or...

Страница 59: ...tion View will be Following the Modify button on the above example the administrator will see a pulldown of configurable choices for the N Ring configuration as below If N Ring Mode is Manager then a...

Страница 60: ...wn if available In any event it is the lowest two installed ports Set Port set table index Ports Designated pair of N Ring ports To reassign different pairs the port sets containing those ports if any...

Страница 61: ...l Ethernet Switch User Manual Installation Guide Page 61 of 132 N Ring Configuration Port Sets Continued Pressing Add on the page above yields The N Ring ports can be selected by pulldown In this mode...

Страница 62: ...eep Alive Timeout The amount of time to wait in seconds to receive a keep alive request before switching from active member back to auto member The default is 31 The range is 15 to 300 seconds with an...

Страница 63: ...efault is 1000 Sign On Match Packets The number of times the switch count must match before starting the sign on process The default is 3 Sign On Interval The interval of time to wait in milliseconds...

Страница 64: ...d Industrial Ethernet Switch User Manual Installation Guide Page 64 of 132 N Ring Status If N Ring mode is inactive Auto Member the following data will be shown If N Ring mode is Active Auto Member th...

Страница 65: ...If the MAC is selected more data will be retrieved and shown about the switch Switch No The number of the switch in the N Ring RM Ring Manager MAC Address The MAC Address of the switch IP Address The...

Страница 66: ...ault N Ring Fault in red near the top of the display Note that the break is identified in red by switches and ports In this case N Ring manager A2 to N Ring active member Switch Number 1 TX2 is broken...

Страница 67: ...e status Enabled or Disabled and the interval between packets Following the Modify button on the above example the administrator can modify the variable to change the frequency with which N View repor...

Страница 68: ...User Manual Installation Guide Page 68 of 132 N View Ports The Ports tab under the N View category will display a list of all the configured ports on the NT24k unit along with the ports transmitting N...

Страница 69: ...nued Following the Modify button on the above example the administrator can modify these two variables to enable or disable N View related multicast out of the port and if MIB stats are sent out for t...

Страница 70: ...ge 70 of 132 Ports Configuration The Configuration tab under the Ports category will show a detailed overview of all the ports on the switch The administrator can view ports that are possible to insta...

Страница 71: ...status of a port It may contain Disable Discarding Learning Forwarding PVID This configurable field displays the existing port VLAN ID setting The allowable range is 1 4094 Trunk ID When the port is a...

Страница 72: ...lays the status including the list of Source Ports and the Destination Port that the Sources are being mirrored to Using the Modify button you can enable the status of port mirroring and select source...

Страница 73: ...ss frame s IEEE802 1p User Priority value if needed based on the QOS settings and the User Priority value if any in the ingress frame Both the internal port priority setting and egress frame User Prio...

Страница 74: ...ttings see QOS SELECTION CHART below The default value is enabled Include 802 1p This configurable field displays the status of whether or not to include the ingress frame s IEEE802 1p User Priority v...

Страница 75: ...t for each of Broadcast Multicast Unknown Unicast and Known Unicast A packet type will be affected when the checkbox is selected if it exceeds the total number of packets subject to the ingress rate l...

Страница 76: ...e example the administrator can modify the Pass Rate Percentage for each and every port The administrator can view ports that are possible to install Modules currently installed or currently linked up...

Страница 77: ...uide Page 77 of 132 Ports Status Statistics Displays the MIB counters for the selected port specified by the Port pull down menu The Clear button will reset all counters for the selected port The Clea...

Страница 78: ...Managed Industrial Ethernet Switch User Manual Installation Guide Page 78 of 132 Ports Status Utilization Shows a bandwidth percentage graph of all the ports The graph is scaled based on the Scale pu...

Страница 79: ...ic characters and the special characters _ and Trunk Ports The ports associated with the trunk Trunk Status The existing status of the trunk It can be either enabled or disabled Notes 1 All ports in t...

Страница 80: ...age 80 of 132 Ports Trunking Continued By selecting the Modify button you can then add delete or modify a trunk group By selecting Add you can first decide to view ports that are possible to install M...

Страница 81: ...Guide Page 81 of 132 Ports Trunking Continued By selecting a trunk ID hyperlink from the Port Trunking Configuration View you can first decide to view ports that are possible to install Modules curre...

Страница 82: ...mation and making configuration changes by using a web browser PPP mode is entered by using the PPP command on the console To change from PPP to CLI mode you must reboot the switch Console Mode CLI Th...

Страница 83: ...ent modes and cannot share links or segments If a port is both an RSTP port and an active N Ring port then the port will be disabled for RSTP 2 Do not create redundant links unless either RSTP or N Ri...

Страница 84: ...time spent in seconds by legacy STP Bridges in transitioning Root and Designated Ports to Forwarding This delays Port transitions until other bridges have received spanning tree information Max Age Se...

Страница 85: ...s bridge is the Root Bridge or is attempting to become the Root Bridge This is the time spent in seconds by legacy STP Bridges in transitioning Root and Designated Ports to Forwarding This delays Port...

Страница 86: ...2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 86 of 132 RSTP Bridge Continued The administrator can modify the Bridge parameters by pressing the Modify button on th...

Страница 87: ...on that VLAN This will show information such as the Path Cost and the Port State If the switch sees a redundant path it will put the port with the highest Path Cost into Blocking mode where it will di...

Страница 88: ...is Disabled Auto Edge Whether or not to use a short timeout when waiting for BPDUs before determining that this is an Edge Port if no BPDUs are received It may have to be disabled for a very large net...

Страница 89: ...ts Only alphanumeric characters are allowed The default is public Read Write Community Name This configurable field represents the Authorized Community Name for SNMP Set requests Only alphanumeric cha...

Страница 90: ...NMP Ttap Stations is done via this page IP Address This field represents the IP Address of the Management Station to be sent SNMP Traps Parameter This field represents the Target Parameter entry TRAPv...

Страница 91: ...ser parameters are shown here for reference only as they are necessary for connecting to the switch securely using an SNMP V3 client when in defaults The default user and other users can be added dele...

Страница 92: ...her or not to replace the VID tag of ingress frames with the port s default VID PVID Discard Untagged Frames For Ports Specifies whether or not untagged ingress frames are dropped by the selected port...

Страница 93: ...ts Specifies whether or not to set the PVID of the member ports to this VLAN ID Remove Ports From Default VLAN When Added To This VLAN Specifies whether or not to remove ports from the Default VLAN wh...

Страница 94: ...d Industrial Ethernet Switch User Manual Installation Guide Page 94 of 132 VLAN Continued Then you can specify general VLAN changes as below in the top frame Pressing Delete in the lower frame of the...

Страница 95: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 95 of 132 VLAN Continued Pressing Add on the screen above allows entry of a new VLAN...

Страница 96: ...2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 96 of 132 VLAN Continued Selecting the Port Number hyperlink in the lower frame of the screen two above allows changes...

Страница 97: ...ernet Switch User Manual Installation Guide Page 97 of 132 Help Overview When the Overview tab of the Help menu is clicked on you will see the Overview page that will have some basic definitions and m...

Страница 98: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 98 of 132 Help Overview Continued...

Страница 99: ...l Installation Guide Page 99 of 132 Help Other This section provides information about fields or links in the top right corner of the page Specific help can be had using the left hand navigation as sh...

Страница 100: ...ide Page 100 of 132 CLI Commands The CLI contains some status and configuration capability The default user password is admin The default password to enter privileged mode is admin Each command includ...

Страница 101: ...T24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 101 of 132 CLI Commands Continued Set IP Mode to static Show the static IP Set a static IP mask and gateway are optional Sav...

Страница 102: ...Revised 4 9 2013 NT24k Managed Industrial Ethernet Switch User Manual Installation Guide Page 102 of 132 CLI Commands Continued Reboot...

Страница 103: ...MulticastFilters UnicastFilters UnicastFilters BridgingConfig BridgingGroup Debug Debug FaultGroup FaultConfig ConfigFaults Fault Contact Disabled Contact Id 0 Id Led Disabled Led Web Disabled Web Fau...

Страница 104: ...sabled Web Fault Fault Contact Enabled Contact Id 7 Id Led Enabled Led Web Enabled Web Fault Fault Contact Enabled Contact Id 8 Id Led Enabled Led Web Enabled Web Fault Fault Contact Enabled Contact I...

Страница 105: ...mpConfig ManualRouterPorts None ManualRouterPorts QuerryMode Auto QuerryMode RemoveUnusedGroups Enabled RemoveUnusedGroups RFilterPorts All RFilterPorts RouterMode Auto RouterMode Status Enabled Statu...

Страница 106: ...ealthyMs SignOnMatch 3 SignOnMatch StatusRefreshRate 6 StatusRefreshRate VlanId 3333 VlanId VlanTagged Tagged VlanTagged NringConfig NringGroup NViewGroup NViewConfig Interval 5 Interval SendAutocastP...

Страница 107: ...tatus Enabled AdminStatus AutoNegotiate Enabled AutoNegotiate CrossOver Auto CrossOver Duplex Full Duplex FlowControl Disabled FlowControl PortNumber A3 PortNumber PortUsageAlarms UsageAlarmHigh 100 U...

Страница 108: ...1 QosPriorityValue Speed 1000 Speed Port Port AdminStatus Enabled AdminStatus AutoNegotiate Enabled AutoNegotiate CrossOver Auto CrossOver Duplex Full Duplex FlowControl Disabled FlowControl PortNumbe...

Страница 109: ...sDSCP Enabled QosDSCP QosPriorityValue 1 QosPriorityValue Speed 1000 Speed Port Port AdminStatus Enabled AdminStatus AutoNegotiate Enabled AutoNegotiate CrossOver Auto CrossOver Duplex Full Duplex Flo...

Страница 110: ...larms PVID 1 PVID Qos8021p Enabled Qos8021p QosDSCP Enabled QosDSCP QosPriorityValue 1 QosPriorityValue Speed 1000 Speed Port Port AdminStatus Enabled AdminStatus AutoNegotiate Enabled AutoNegotiate C...

Страница 111: ...geAlarmHigh UsageAlarmLow 0 UsageAlarmLow PortUsageAlarms PVID 1 PVID Qos8021p Enabled Qos8021p QosDSCP Enabled QosDSCP QosPriorityValue 1 QosPriorityValue Speed 1000 Speed Port Port AdminStatus Enabl...

Страница 112: ...rtNumber PortUsageAlarms UsageAlarmHigh 100 UsageAlarmHigh UsageAlarmLow 0 UsageAlarmLow PortUsageAlarms PVID 1 PVID Qos8021p Enabled Qos8021p QosDSCP Enabled QosDSCP QosPriorityValue 1 QosPriorityVal...

Страница 113: ...Duplex FlowControl Disabled FlowControl PortNumber C4 PortNumber PortUsageAlarms UsageAlarmHigh 100 UsageAlarmHigh UsageAlarmLow 0 UsageAlarmLow PortUsageAlarms PVID 1 PVID Qos8021p Enabled Qos8021p Q...

Страница 114: ...toNegotiate CrossOver Auto CrossOver Duplex Full Duplex FlowControl Disabled FlowControl PortNumber C7 PortNumber PortUsageAlarms UsageAlarmHigh 100 UsageAlarmHigh UsageAlarmLow 0 UsageAlarmLow PortUs...

Страница 115: ...3 RateLimit UnknownUnicast Disabled UnknownUnicast Limit Limit Broadcast Enabled Broadcast KnownUnicast Disabled KnownUnicast Multicast Disabled Multicast PortNumber A3 PortNumber RateLimit 3 RateLim...

Страница 116: ...er RateLimit 3 RateLimit UnknownUnicast Disabled UnknownUnicast Limit Limit Broadcast Enabled Broadcast KnownUnicast Disabled KnownUnicast Multicast Disabled Multicast PortNumber B1 PortNumber RateLim...

Страница 117: ...knownUnicast Disabled UnknownUnicast Limit Limit Broadcast Enabled Broadcast KnownUnicast Disabled KnownUnicast Multicast Disabled Multicast PortNumber B7 PortNumber RateLimit 3 RateLimit UnknownUnica...

Страница 118: ...knownUnicast Limit Limit Broadcast Enabled Broadcast KnownUnicast Disabled KnownUnicast Multicast Disabled Multicast PortNumber C5 PortNumber RateLimit 3 RateLimit UnknownUnicast Disabled UnknownUnica...

Страница 119: ...tpMac Auto AdminPtpMac AutoEdge Enabled AutoEdge PathCost Auto PathCost PortNumber A1 PortNumber PortPriorityStep 128 PortPriorityStep VlanId 1 VlanId Port Port AdminEdge Disabled AdminEdge AdminPtpMa...

Страница 120: ...uto PathCost PortNumber A6 PortNumber PortPriorityStep 128 PortPriorityStep VlanId 1 VlanId Port Port AdminEdge Disabled AdminEdge AdminPtpMac Auto AdminPtpMac AutoEdge Enabled AutoEdge PathCost Auto...

Страница 121: ...lanId Port Port AdminEdge Disabled AdminEdge AdminPtpMac Auto AdminPtpMac AutoEdge Enabled AutoEdge PathCost Auto PathCost PortNumber B4 PortNumber PortPriorityStep 128 PortPriorityStep VlanId 1 VlanI...

Страница 122: ...dge PathCost Auto PathCost PortNumber C1 PortNumber PortPriorityStep 128 PortPriorityStep VlanId 1 VlanId Port Port AdminEdge Disabled AdminEdge AdminPtpMac Auto AdminPtpMac AutoEdge Enabled AutoEdge...

Страница 123: ...ityStep 128 PortPriorityStep VlanId 1 VlanId Port Port AdminEdge Disabled AdminEdge AdminPtpMac Auto AdminPtpMac AutoEdge Enabled AutoEdge PathCost Auto PathCost PortNumber C7 PortNumber PortPriorityS...

Страница 124: ...otifyView Prefix Prefix ReadView mibView ReadView Status 1 Status Storage 3 Storage WriteView WriteView V3Access V3Access GroupName mibNotify GroupName Level 1 Level Match 1 Match Model 0 Model Notify...

Страница 125: ...Name set SecurityName Status 1 Status Storage 3 Storage TransportTag TransportTag V3Community V3Community CommunityName public CommunityName ContextEngineId 80006edd030007af7d9560 ContextEngineId Cont...

Страница 126: ...ibRead GroupName Model 1 Model Status 1 Status Storage 3 Storage UserName get UserName V3Group V3Group GroupName mibRead GroupName Model 2 Model Status 1 Status Storage 3 Storage UserName get UserName...

Страница 127: ...80006edd030007af7d9560 ContextEngineId ContextName ContextName MultipleTargetOut group1 MultipleTargetOut ProxyName trap_proxy ProxyName ProxyType 3 ProxyType SingleTargetOut SingleTargetOut Status 1...

Страница 128: ...SingleTargetOut addr1 SingleTargetOut Status 1 Status Storage 3 Storage TargetParamsIn NoAuthNoPriv md5 TargetParamsIn V3Proxy V3Proxies V3TargetAddresses TargetAddresses TargetAddresses TargetParame...

Страница 129: ...SecName Status 1 Status Storage 3 Storage TargetParameter TargetParameters V3TargetAddresses V3Users V3User AuthKey 76d0e46ae1b32272fc21083d89678840 AuthKey AuthPassword AuthPassword AuthProt 1 AuthPr...

Страница 130: ...ta Data Type SwitchName Type ClientId FallbackEnable Enabled FallbackEnable FallbackGateway 0 0 0 0 FallbackGateway FallbackIPAddress 192 168 1 201 FallbackIPAddress FallbackSubnet 255 255 255 0 Fallb...

Страница 131: ...me admin Username WriteAccess 4 WriteAccess User Users UserConfig UserGroup VlanGroup VlanConfig IngressDiscardUntagged None IngressDiscardUntagged IngressReplaceVID Disabled IngressReplaceVID Ingress...

Страница 132: ...for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT O...

Отзывы: