First-Time Configuration
Manual No. 775029
1-7
❑
Option 1: Do an Automatic Configuration.
The RAID Configuration Summary screen is displayed showing the
recommended configuration for your system (Figure 1-4).
Figure 1-4. RAID Configuration Summary Screen
Table 1-2. RAID Configuration Summary Fields
Field
Description
Fault Tolerance
For 1 disk drive = No
For 2 or more disk drives = Yes
Spare
For 1-3 disk drives = No
For 4-8 disk drives = Yes
Optimization
For 1 disk drive = Performance (no fault tol)
For 2 disk drives = Performance
For 3 or more disk drives = Capacity
Logical Drive Count
1
Total (Useable) Capacity
Depends on the fault tolerance overhead:
For 1 disk drive of n GB = n GB
For 2 disk drives of n GB = n GB
For 3 disk drives of n GB = 2n GB
For 4,5,6,7,8 disk drives of n GB =
2n,3n,4n,5n,6n GB respectively
a
a. With four or more drives, one drive’s capacity is used for fault tolerance
overhead, and one additional drive is reserved as a spare.
Disk Drive Identification
Depends on disk drives.