Drive Configuration
Manual No. 775029
2-73
3. For spanning, capacity of the drives in a disk array does not need to be
the same, but each disk array must have the same number of physical
drives and be defined consecutively.
To avoid downsizing of drives, build each disk array with drives of the
same capacity whenever possible. Therefore, you can span an array of
three (3) 4.0 GB drives with a second, consecutively-defined array of
three 2.0 GB drives.
Spanning Limitations
Spanning has specific limitations as well:
1. You will NOT be able to add capacity to (expand) any array that has
been spanned. Therefore, the Add Capacity to Existing Disk Array
option on the Custom Configuration menu will not allow you to choose
any spanned arrays.
2. The RAID levels that will be available for logical drives in a spanned
set depend entirely on the number of physical drives in each of the
spanned arrays, NOT on the total number of drives. See Table 2-6 for
an example.
Table 2-6. RAID Levels in Spanned Configurations
Note that assignment of spare drives reduces the number of available,
unconfigured drives, and therefore affects the allowable RAID levels.
For example, if you span two three-drive arrays, but one drive in each
array is assigned as a spare, you will only be able to select RAID 00 or
RAID 10 for the spanned arrays’ logical drive(s).
Given the background information above, let’s begin!
Array Configuration
Possible RAID Levels for Logical Drives
A0 = 2 drives
A1 = 2 drives
RAID 00 (= spanned RAID 0, no fault tolerance)
RAID 10 (= spanned RAID 1)
A0 = 3+ drives
A1 = 3+ drives
RAID 00 (= spanned RAID 0, no fault tolerance)
RAID 30 (= spanned RAID 3)
RAID 50 (= spanned RAID 5)
RAID 0+1+0 (= spanned RAID 0+1)
A0 = 2 drives
A1 = 2 drives
A2 = 2 drives
RAID 00 (= spanned RAID 0, no fault tolerance)
RAID 10 (= spanned RAID 1)
Two drives per array, no matter how many consecutive
arrays exist, is still limited to RAID 00 or RAID 10.