15. Take the model and putty out of the oven, place the tip of the
injector into the putty indent and squeeze the trigger once and
hold the trigger in the pulled position keeping pressure on the
injection for 5 seconds. Do not repeatedly pull the trigger.
IF
CREATING A SECOND CLASP ON THE SAME PARTIAL,
REMOVE THE INJECTOR FROM THE PUTTY, CLEAN THE
TIP, AND ALLOW THE INJECTOR TO SIT FOR ONE MINUTE.
THEN INJECT THE SECOND CLASP FOLLOWING THIS
SAME PROCEDURE.
16. Expel the remaining material onto the Elite gun stand and
remove the rod. While wearing heat resistant gloves, remove
sleeve and nozzle from gun and place on metal stand to cool.
Refer to Section 5 for more information regarding cleaning
of the sleeve and nozzle. Let the model bench set for about
10 minutes or until the model is cool to the touch.
17. Section the putty matrix using a thin bladed knife. Cut a
section of the putty with the knife and using an instrument,
pry off the pieces of the putty until all the putty is removed.
11
myerson HOTSHOTELITE MANUAL ENGLISH.indd 11
3/23/10 9:54:39 AM