13. When the timer sounds, place the Injection Rod into the back
of the injector with the teeth facing down. Push the rod into the
injector until it contacts the molten material. Squeeze the trigger
and discharge the aerated molten material onto the supplied
injector base until the ring on the injection rod reaches the back
of the injector. For safety reasons, expel molten material on to
Elite injector stand only. The material will not stick and is easily
removed once cooled. Allow the material to fully cool before
removing and wear supplied safety gloves.
DO NOT ATTEMPT TO REUSE INJECTED MATERIAL
.
This process is important to keep aerated material from
becoming part of the final clasp or appliance.
14. After priming the myerson
HotShotElite
for injection, use the
supplied gloves to clear off the tip of the injector with your finger.
If material bulges from tip after cleaning, pull back on the
injection rod about 3mm. This will take the pressure off the
material and keep it from bulging out the tip.
A bulge from
the injector tip can cool quickly and possibly plug the sprue
during injection. Pay attention not to allow a plug to form.
This may cause an incomplete injection.