mychefcooking.com
TECHNICAL SUPPORT SERVICE MANUAL iCOOK | iBAKE | COOK | BAKE | SNACK | BAKERSHOP - DT.MS.CB.2202.2
27
The table below shows the different errors and alarms, as well as possible solutions to them.
Error
Internal definition
Clarification
0
NO ERROR
No error.
1
GENERAL PURPOSE INPUT ERROR
General error input. Not used.
2
ERROR OVERTEMPERATURE
General temperature input. Not used.
3
ERROR OVERTEMPERATURE PCB
Overtemperature PCB. Check that the cooling fans of
the electronics are working properly, that there is
enough space between the back and the wall, and
that the ambient temperature is not too high.
4
ERROR COMMUNICATION
Communication between boards is not responding.
Check the cable connecting the power board and the
control board.
4.1
PCB ERROR RELAYS
Communication between boards is not responding.
Check wiring.
4.3
INVERTER ERROR
Communication between boards is not responding.
Check wiring.
4.5
ERROR GAS
Communication between boards is not responding.
Check wiring.
4.6
ERROR GAS
Communication between boards is not responding.
Check wiring
4.7
HOOD ERROR
Communication between boards is not responding.
Check wiring.
4.8
PROOFER ERROR
Communication between boards is not responding or
sensors not responding. Check wiring.
4.9
STATIC OVEN ERROR
Communication between boards is not responding or
sensors not responding. Check wiring.
5
EEPROM ERROR
Processor and EEPROM communication does not
work. Check the control board.
6
ENGINE ERROR
Motor
error.
Check
motor
wiring.
Motor
overtemperature. Motor stuck.
7
ALARM WATER
No water detected. Make sure that the water network
is correctly connected. Not used.
8
ERROR WASHING
No detergent/rinse aid detected. Not used.
9
ERROR PROBE1 TEMP SENSOR
NOT CONNECTED
External probe not connected. Check external probe
and connector. Not used.
10
ERROR PROBE1 TEMP SENSOR
SHORTED
External probe short-circuited. Check external probe
and connector. Not used.
11
ERROR PROBE2 TEMP SENSOR
NOT CONNECTED
External probe not connected. Check external probe
and connector. Not used.
12
ERROR PROBE2 TEMP SENSOR
SHORTED
External probe short-circuited. Check external probe
and connector. Not used.
13
ERROR PROBE3 TEMP SENSOR
NOT CONNECTED
External probe not connected. Check external probe
and connector. Not used.
14
ERROR PROBE3 TEMP SENSOR
SHORTED
External probe short-circuited. Check external probe
and connector. Not used.