Relay No.
Definition
1*
Not used. When this relay is activated, relay 17 (Cooling 12V) is also activated.
2
Contactor.
3*
Not used. When this relay is activated, relay 16 (12V light) is also activated.
4
Chimney.
5
Steam solenoid valve.
6*
Condensate cooling solenoid valve.
7
Siphon filler solenoid valve (rinsing)
8*
Self-cleaning recirculation pump.
9*
Siphon drain pump.
10
Reserved.
11
Reserved.
12
Reserved.
13
Speed 1.
Engine
14
Speed 2.
15
CW/ACW
16
Virtual relay. Speed 1 + CW/ACW
*Includes functions only available in the 17-relay electronics board.
Tabla 4.
Relay test allocations
To activate them, the following process must be carried out:
•
Select record 05 of block P3 and press the PROG button to edit the value.
•
Use the display to navigate through the 17 (1...16) possibilities and choose the
number related to the relay to be tested.
•
Press the STEP button to activate the relay. The electrical contact will remain closed
as long as the button is pressed.
•
We can vary the number and press STEP to activate the desired relays as many times
as necessary.
•
At the end of the test, press the M3 button to return to the configuration menu.
With this process it is possible to check that all relays are activated and deactivated correctly,
as well as to make sure that all elements connected to each relay, such as lights, pumps and
motors, are working properly.