TECHNICAL SUPPORT SERVICE MANUAL iCOOK | iBAKE | COOK | BAKE | SNACK | BAKERSHOP - DT.MS.CB.2202.2
28
15
ERROR PROBE4 TEMP SENSOR
NOT CONNECTED
Reserved. Not used.
16
ERROR PROBE4 TEMP SENSOR
SHORTED
Reserved. Not used.
17
ERROR PROBE5 TEMP SENSOR
NOT CONNECTED
Reserved. Not used.
18
ERROR PROBE5 TEMP SENSOR
SHORTED
Reserved. Not used.
19
ERROR PROBE6 TEMP SENSOR
NOT CONNECTED
Reserved. Not used.
20
ERROR PROBE6 TEMP SENSOR
SHORTED
Reserved. Not used.
21
ERROR PROBE7 TEMP SENSOR
NOT CONNECTED
Reserved. Not used.
22
ERROR PROBE7 TEMP SENSOR
SHORTED
Reserved. Not used.
23
ERROR PROBE8 TEMP SENSOR
NOT CONNECTED
Chamber probe not connected. Check probe and
wiring.
24
ERROR PROBE8 TEMP SENSOR
SHORTED
Short-circuited chamber probe. Check probe and
wiring.
25
ERROR PROGRAM NOT
TERMINATED
Reserved. Not used.
26
ERROR CLEANING PROGRAM NOT
TERMINATED
The oven has been switched off by running a self-
cleaning programme. Perform a rinse. Not used.
27
ERROR CLEANING TEMPERATURE
TOO HOT
The oven temperature during a self-cleaning
programme has risen above a maximum temperature.
Not used.
28
ALARM RECOVERY TEMP TOO
LOW
The oven has recovered from a power failure, and the
temperature in the chamber was below 56ºC. Risk of
bacterial contamination. Discard or analyse the
product in the cooking chamber. Not used.
29.XXXX
INVERTER ERROR
Inverter error. Consult code with the technical service.
30.XX
GAS SAFETY ERROR
Gas safety error. Consult code with the technical
service.
Tabla 1.
Errors, alarms, and possible solutions
Once the equipment has detected a serious error, it will not be able to function normally
until it is repaired.
Due to automatic checks, the equipment may shut down to avoid a serious failure. Proceed
to switch it on as normal.