7.2.9 How to check the Power Supply Voltages/ 100 V AC, 200 V AC
Step 1 :
Turn off the Power Switch and open the Control Box.
(The Power Cable may remain connected.)
Step 2 :
With the Power Switch off, check that 100 to 120 V AC or 200 to 240 V AC is being output
between pins 2 and 3 of connector J001 on the Power Board.
If not, take the following steps to identify the cause:
•
Is the power outlet providing 100 to 120 V AC or 200 to 240 V AC?
•
Replace the Power Cable.
•
Replace the Power Board Assembly.
Step 3 :
Turn on the Power Switch and check that 100 to 120 V AC or 200 to 240 V AC is being output
between pins 4 and 6 of connector J002 on the Power Board.
•
Replace the fuse if it is blown.
•
Replace the Power Switch Assembly.
•
Replace the Power Board Assembly.
Содержание Rockhopper 38
Страница 1: ...Maintenance Manual MUTOH EUROPE N V AP 74038 Rev 1 1 25 01 2005 ...
Страница 2: ...Rockhopper 38 Maintenance Manual 2 AP 74038 Rev 1 1 25 01 05 ...
Страница 4: ...Rockhopper 38 Maintenance Manual 4 AP 74038 Rev 1 1 25 01 05 ...
Страница 6: ...Rockhopper 38 Maintenance Manual 6 AP 74038 Rev 1 1 25 01 05 ...
Страница 15: ...Rockhopper 38 Maintenance Manual 15 AP 74038 Rev 1 1 25 01 05 1 2 3 4 ...
Страница 16: ...Rockhopper 38 Maintenance Manual 16 AP 74038 Rev 1 1 25 01 05 5 6 7 8 9 ...
Страница 26: ...Rockhopper 38 Maintenance Manual 26 AP 74038 Rev 1 1 25 01 05 ...
Страница 32: ...Rockhopper 38 Maintenance Manual 32 AP 74038 Rev 1 1 25 01 05 ...
Страница 112: ...Rockhopper 38 Maintenance Manual 112 AP 74038 Rev 1 1 25 01 05 ...
Страница 146: ...Rockhopper 38 Maintenance Manual 146 AP 74038 Rev 1 1 25 01 05 ...
Страница 152: ...Rockhopper 38 Maintenance Manual 152 AP 74038 Rev 1 1 25 01 05 ...
Страница 257: ...Rockhopper 38 Maintenance Manual 257 AP 74038 Rev 1 1 25 01 05 DE 10875B UNIT SDMP38 CAT5009 00 REV ...
Страница 258: ...Rockhopper 38 Maintenance Manual 258 AP 74038 Rev 1 1 25 01 05 ...