41
3
Deskew
Image skew generally occurs when the
originals are loaded at a skew angle in the
Input tray. check this function to automatically
correct skewed pages approxi/-15
degrees.
Original
Deskew applied
•
Deskew is only enabled when the Scan
Size set to “Auto”.
•
Originals with darker backgrounds and
dark text are difficult to deskew. Deskew
may not work properly when deskewing
dark images.
•
this function cannot work with a large
skew angle.
4
Stop Scanning
After multi-Feed
A multi-feed occurs when two or more sheets
stuck together when being fed through the
Scanner. With this function checked, the
Scanner will automatically stop with a dialog
box when it detects a multi-feed, asking you to
check your documents.
NOTE:
If the multi-Feed detection operates
incorrectly, click [
i
] (information) at the
bottom right of the iDocScan touch panel, then
adjust the “multi-Feed Detection Sensitivity”
level. Set “high” when the multi-feed cannot
be detected even when more than one sheet
was fed at a time. Set “low” when the multi-
feed is detected even when only sheet was fed
at a time.
NOTE:
Uncheck this box when scanning business
cards, plastic and embossed cards, or when a
false multi-feed occurs frequently.
NOTE:
When paper jams occur, be sure to clear
SettING IDOcScAN tOUch
(cONtINUeD)
Содержание idocscan p45