PGN
65532 (0xFFFC)
PDU Format
255 (0xFF)
PDU Specific
252 (0xFC)
Source Address
224 (0xE0) SA Offset of 0
Built Message
(0x
18FFFCE0
)
Status Message DPLF2
PGN
65532 (0xFFF3)
PDU Format
255 (0xFF)
PDU Specific
243 (0xF3)
Source Address
224 (0xE0) SA Offset of 0
Built Message
(0x
18FFF3E0
)
Status Message DPLT1
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0
Name
Data Type
Byte
Bits
Description
CNFG1
Byte
1
All
Hardware Configuration
CNFG2
2
PCB Assembly Revision
VBAT
10 Bit
3
Battery Voltage
4
1, 2
TEMP
12 Bit
5
All
Module Temperature
6
1, 2, 3, 3
CNFG3
Byte
7
All
Additional Configuration
8
Not Used
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0
Status Message 4 (Ouput Amperage Feedback OUT 1A-4B)
Name
Data Type
Byte
Bits
Description
Output 1A Feedback (Amps)
Byte
1
Amp Data Range 0.0 to 22.0 Amps [0 – 220 decimal]
Output 1B Feedback (Amps)
2
Amp Data Range 0.0 to 22.0 Amps [0 – 220 decimal]
Output 2A Feedback (Amps)
3
Amp Data Range 0.0 to 22.0 Amps [0 – 220 decimal]
Output 2B Feedback (Amps)
4
Amp Data Range 0.0 to 22.0 Amps [0 – 220 decimal]
Output 3A Feedback (Amps)
5
Amp Data Range 0.0 to 22.0 Amps [0 – 220 decimal]
Output 3B Feedback (Amps)
6
Amp Data Range 0.0 to 22.0 Amps [0 – 220 decimal]
Output 4A Feedback (Amps)
7
Amp Data Range 0.0 to 22.0 Amps [0 – 220 decimal]
Output 4B Feedback (Amps)