Section 80
00-02-0829
2018-02-26
-
46 -
4.5.4 Analog Inputs 7-8, Software Version and Power Supply
CAN message sent by the PDM to communicate the measured values.
Transmission Repetition
20 – 500 ms
Data Length
8 bytes
Data Page
0
PDU Format (PF)
239
Proprietary A, PDU1 format
PDU Specific (PS)
17 (11h)
DA (Source Address of the configuring display or
controller)
Priority
5
Parameter Group Number
61184 (EF00h) -
Feedback and Diagnostics
Start Position Length
Parameter Name
Reference
1
1 byte
Feedback and Diagnostics Identifier
2.1
1 bit
Total Current Status
2.2
1 bit
Power Supply Status
3
2 bytes
Software Version
5
2 bytes
Analog Input 7
7
2 bytes
Analog Input 8
Содержание Xpansion IX3212