Section 80
00-02-0829
2018-02-26
-
35 -
4.4.1 Command Output Channels
The command output channels message sets the PWM value of each output channel. The
message bytes refer to outputs 1-6 or 7-12, depending on the value of the identifier in the first
byte.
NOTE:
A Command message must be broadcast to the PDM at least
once every second. Otherwise the PDM enters the Loss of
Communication state.
CAN message sent to the PDM to drive the outputs.
Transmission Repetition
20 – 500 ms
Data Length
8 bytes
Data Page
0
PDU Format (PF)
239
Proprietary A, PDU1 format
PDU Specific (PS)
30 (1Eh) or as set
DA (Source Address of the PDM)
Priority
5
Parameter Group Number
61184 (EF00h)
Start Position Length
Parameter Name
Reference
1
1 byte
Output Command Identifier
2
1 byte
Command (Output Channel 1 or 7)
3
1 byte
Command (Output Channel 2 or 8)
4
1 byte
Command (Output Channel 3 or 9)
5
1 byte
Command (Output Channel 4 or 10)
6
1 byte
Command (Output Channel 5 or 11)
7
1 byte
Command (Output Channel 6 or 12)
8.1
1 bit
Enable (Output Channel 1 or 7)
8.2
1 bit
Enable (Output Channel 2 or 8)
8.3
1 bit
Enable (Output Channel 3 or 9)
8.4
1 bit
Enable (Output Channel 4 or 10)
8.5
1 bit
Enable (Output Channel 5 or 11)
8.6
1 bit
Enable (Output Channel 6 or 12)
8.7
2 bits
Module Transmit Rate / Unused