Section 80
00-02-0829
2018-02-26
-
40 -
4.5.1.1 Feedback and Diagnostics Identifier
All feedback and diagnostic messages contain a unique identifier which determines the associated information.
128 (80h) Analog Inputs 1-2, Digital Inputs
129 (81h) Analog Inputs 3-4, Output Diagnostics
130 (82h) Analog Inputs 5-6, Battery and Sensor Supply
131 (83h) Analog Inputs 7-8, Miscellaneous Feedback
132 (84h) Outputs 1-6 Feedback
133 (85h) Outputs 7-12 Feedback
134 (86h) Motor Model Handshake
135 (87h) Output Configuration Handshake Channels 1-6
136 (88h) Output Configuration Handshake Channels 7-12
Data Length:
1 byte
Resolution:
1 state / 1 byte
0 offset
Data Range:
0
Operational Range: same as data range
Type:
Status (command)
PGN:
PGN 61184 –
Feedback and Diagnostics
4.5.1.2 Digital Inputs
Three states describe each digital input.
00 Open Circuit
01 Short-to-ground
10 Short-to-battery
11 Not Available
Data Length:
2 bits
Resolution:
3 states / 2 bits
0 offset
Data Range:
-
Operational Range: same as data range
Type:
Status (measured)
PGN:
PGN 61184 –
Feedback and Diagnostics