10. WIRE CONTROLLER (KJR-120D/BMK-E)

1. Safety precautions 

The following contents are stated on the product and the operationmanual, includ-

ing usage, precautions against personal harm and property loss, and the methods 

of  using  the  product  correctly  and  safely. After  fully  understanding  the  following 

contents (identifiers and icons), read the text body and observe the following rules. 

  

Identifier description 

Identifier

Meaning
Means improper handling may lead to personal death or

severe injury.
Means improper handling may lead to personal injury or

property loss.

[Note]: 1. “Harm” means injury, burn and electric shock which need long-term 

                 treatment but need no hospitalization.

            2. “Property loss” means loss of properties and materials. 

  

Icon description 

Meaning

lcon

It indicates forbidding. The forbidden  subject-matter is indicated in the 

icon or by images or characters aside.

It indicates compulsory implementation. The compulsory subject-matter

is indicated in the icon or by images or characters aside. 

Warning

Caution

  

Warning

Warning

Please entrust the distributor or professionals to install 

the  unit.  The  installers  must  have  the  relevant  know-

how.Improper installation performed by the user without 

permission  may  cause  fire,  electric,shock,  personal 

injury or water leakage. 

Delegate
installation

Forbid

Forbid

Usage

Warning

Do not spray flammable aerosol to the wire

controller directly. Otherwise, fire may occur.

Do not operate with wet hands or let water enter the wire

controller. Otherwise, electric shock may occur.

Please entrust the distributor or professionals to install the unit. 

Imporper installation may lead to electric shock or fire.  

WARNING 

CAUTION

For  protecting  the  device,  do  not  repeatedly  or  quickly  shift  modes.  Each  wire 

controller operation to off the unit, it must be waited for 3 minutes or waited for all 

the units stopped then can re-operate the wire controller to start the outdoor unit.
The wire controller is supplied 10V AC current by the adapter.  
Do not install the unit in a place vulnerable to leakage of flammable gases. Once 

flammable gases are leaked and left around the wire controller, fire may occur.  

2. Overview of wired controller 

2.1 Basic conditions of operating the wired controller

: 

2.2 Main functions of this wire controller as follows:

1)  Applicable range of supply voltage:Input voltage is 10V AC. 
2)  Operating environment temperature of wired controller: -10°C~+43°C. 
3) Operating RH of wired controller: RH 40%~RH90%. 

1)  Touch key operation;
2)  LCD displays  operation parameters; 
3)  Multiple timer; 
4)  Buzzer prompt tone and alarm functions;
5)  Real-time clock function. 

3. Overview

Fig.3-1

14 

13 

16 

11 

15 

10 

11 

12 

1. Operation icon 

2. Mode area

3. Setting temperature

4. Timing On/Off

5. Function Icon

6. On-line Unit Qty. Indication 

7. Reserved

8. Clock
9. Water temp.

10.ON/OFF Key
11.Right, Left Right Key
12.OK key
13. Setting key
14. Add, Reduce key
15. Cancel key
16. Reserved

. key

(Press for 3sec to 

cancel timer)

(Press for 3sec to

unlock)

AUXILIARY 

 

Operation icon 

      

:

 Indicate the ON and OFF status; when it is ON, it will display; when 

it is OFF, it will disappear;  

Mode area:

 Indicate the main unit operating mode; details refer to Page 15;

Setting temperature: 

2 status can be displayed:                     ;

Timing ON/OFF indication                 

: Indicate the timing information; details refer to 

Page 10; 

Function icon 

1) Computer: Display when connects to computer;
2) Maintenance: When the icon is lighted on it means should arrange professionals to 

do the cleaning maintenance; long press “AUXILIARY” for 3 seconds then this icon will 
be off, until the next maintenance;  

3) E-heating: Display when the electric auxiliary heating water function is operated; 
4) Check: Display when check function is operated;
5) Anti-freezing: Display when the main unit ambient temperature is below 2

, to 

 remind the main unit should be do the anti-freezing measurement;

6) Lock: When the icon is lighted on, it means the button has been locked (no keys 

operation  for 2 minutes ), long press “OK” key for 3 seconds to unlock;

7) Error: When the main unit has error or protection, this icon will be displayed.  The unit 
      need to be maintained by professionals. 

10 

11 

12 

13 

14 

15 

16 

On-line unit qty. indication:

 Under normal status display the quantity of the units connected 

to the wire controller; under check status display the device serial number;

Reserved

;

Clock:

Under normal status display clock; during timing setting it displays the setting timing 

time, details refer to Page 10;

Water temperature:

 Under normal status display water temperature; during water temperature 

setting it displays the setting numerical value; 

under the check status display  check parameter; 

ON/OFF key: 

On and Off functions;

Right, Left key:

 Under main page to press this key can query the setting water temperature,

setting timing etc; during timing setting press the right key then shift to the next step setting; 
during spot check they are used to turn over the unit parameter information;

OK key:

 After setting the parameter then press this key to confirm. After keys locking then long 

press this key for 3 seconds to unlock;

Setting  key: 

Setting  the  water  temperature,  timing,  mode  etc,    long  press  this  key  for  3 

seconds enter to the check;

Add, Reduce key: 

Setting water temperature, timing, water level etc; during spot

check they are used to read over #0

#15 units;

Cancel key:

 During setting parameters press this key to cancel setting. After timing setting 

and then long press this key 3 seconds to cancel timing;

Reserved key

.

Modular Chiller MUEN-H6

Содержание MUEN-65-H6T

Страница 1: ...MODULAR CHILLER MUEN H6 English CL25617 MUEN 65 H6T Installation Owner s manual www mundoclima com ...

Страница 2: ...ontrol box Water inlet MAIN PARTS OF THE UNIT Temperature testing compo nents of total water outlet Purpose Shape Qty Unit Wire control assembly ACCESSORIES Installation Operation Manual Use for installation only need for setting the main module Installation manual of wire controller AUXILIARY 1 1 1 1 ...

Страница 3: ...atically conduct energy control according to the magnitude of load to achieve optimal matching and thus actually realizing optimal energy saving operation The product is modularized unit and parallel connection of 16 modules can be realized at most so the user can adopt module combination according his own demands The product can be widely applied in air conditioning engineering of various newly b...

Страница 4: ...g injuries Never inspect or service the unit by yourself Ask a qualified service person to perform this work Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary Keep far away from high frequency equipment Keep away from the following places a place where it is full of oil gas places where salty air surrounding near the coas...

Страница 5: ... health of those who are hypersensitive to chemicals Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the indoor unit It may cause incomplete combuston or deformation of the unit due to the heat Do not install the air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may...

Страница 6: ...oid affecting the people due to transfer of noise and vibration The base of the unit is provided with installation holes which can be used to connect the unit and the foundation firmly 3 1 7 In case of installation on the roof the roof must possess enough strength to sustain weight of the unit and maintenance personnel The unit can be supported on concrete foundations or channel steel frames simil...

Страница 7: ...nd the space between adjacent modular units should not be less than 300mm the installation can also follow the direction B and C as shown in Fig 3 2 the spaces between the unit and the obstacle are given in Table 3 1 and the space between adjacent modular units should not be less than 600mm the installation can also follow the direction combina tion of A and D and B and C the spaces between the un...

Страница 8: ...mance of the unit will decline c The inlet pipe of the evaporator must be provided with a target flow controller to realize flow break protection for the unit Both ends of the target flow controller must be supplied with horizontal straight pipe sections whose diameter is 5 times that of the inlet pipe The target flow controller must be installed in strict accordance with Installation Regulation G...

Страница 9: ...in winter For the water pipeline network including filters and heat exchangers dreg or dirt may seriously damages the heat exchangers and water pipes The installation persons or the users must ensure the quality of chilled water and de icing salt mixtures and air should be excluded from the water system since they may oxidize and corrode steel parts inside the heat exchanger o The common outlet pi...

Страница 10: ...ater flow in terms of multi connect the units that water flow must no less than total units rated water flow b Select the left of the pump H h1 h2 h3 h4 H The lift of the pump h1 Main unit water resistance h2 Pump water resistance h3 Water resistance of the longest water loop distance includes pipe resistance different valve s resistance flexible pipe resistance pipe elbow and three way resistance...

Страница 11: ... adjustment is done c When wiring connection is conducted adjustment of other screws except connection terminals of micro switches and ground screws is prohibited In the meanwhile over great force should not applied when wires of micro switches are connected otherwise micro switches may suffer displacement thus leading to failure of flow switches Fig 4 3 Fig 4 4 4 10 Installation of single module ...

Страница 12: ...No n module No n 1 address No 1 module No n 1 module No n 2 address No 0 address Water flow switch Pump Fig 4 6 less than 6 modules b Installation mode II recommended installation mode No n module No n 1 address No 1 module No n 1 module No n 2 address No 0 address Pump Fig 4 7 installation mode A less than 16 modules Water flow switch Drill dead hole at the position and move the total effluent te...

Страница 13: ...ensing bulb target flow controller and auxiliary electric heater are under control of the main module One wired controller and one target flow controller are required and connected on the main module The unit can be started up through the wired controller only after all addresses are set and the aforementioned items are determined The wired controller is 500m away from the outdoor unit ŏ4ŏ ψ4ŏ ψ4ŏ...

Страница 14: ...apacitance suppressors to avoid electromagnetic interference thus leading to failure of the unit and its controller and even damages to them 5 3 10 All weak current wires led to the electric box must apply shielded wires which must be provided with grounding wires The shield wires and power supply wires should be laid separately to avoid electromagnetic interference 5 3 11 The unit must be provide...

Страница 15: ...it as shown in Fig 5 2 Step 11 Connection of control wires of pump the control wires of AC contactor of pump must pass the connection terminals p1 and P2 of the main unit as shown in Fig 5 3 Step 12 The connection way of the wire controller connects with every signal wires from package units signal wires P Q E are connected in the same way of main wires connection method and accordingly connect to...

Страница 16: ... and OFF Total outlet water temperature sensor fault code E3 Only the main unit is valid and the subordinate units are invalid Under refrigerating mode and heating mode conduct adjustment according to the magnitude of total outlet watertemperature Adjustment range Load stabilize unload Emergency Stop 7 8 No Table 5 2 Detection of current of the compressor B1 protection code P5 Current is not detec...

Страница 17: ... pressure protection of the system A and discharge temperature switch protection protection code P0 high pressure protection of the system B and discharge temperature switch protection protection code P2 low pressure protection of the system A protection code P1 low pressure protection of the system B protection code P3 Constant speed compressor connection of discharge temperature switch and high ...

Страница 18: ... or protection code is displayed Four way valve of the system B Neutral wire Four way valve of the system A Neutral wire Outdoor fan A controlled by T4 Outdoor fan B controlled by T4 PWM pressure relif valve control for digital compressor Input of three phase four wire power supply fault code E1 Three phases A B and C of power supply should exist simultaneously and the difference of phase angle sh...

Страница 19: ...Check item table after installation Checking item Description Yes No Whether installing site is meet for requirements Whether water system is meeting for requirements Whether electric wiring system is meeting for requirements Units are fixed mounting on level base Ventilating space for heat exchanger at the air side is meeting for requirement Maintenance space is meeting for requirement Noise and ...

Страница 20: ...ty Do not re start the unit within 10 min after the unit is shut down during trial run When the unit is used frequently do not cut off the power supply after the unit is shut down otherwise the compressor cannot be heated thus leading to its damages If the unit is not in service for a long time and the power supply needs to be cut off the unit should be connected to the power supply 12 hours prior...

Страница 21: ...oller the check sequence is as follows ON OFF key On and Off functions Right Left key Under main page to press this key can query the setting water temperature setting timing etc during timing setting press the right key then shift to the next step setting during spot check they are used to turn over the unit parameter information OK key After setting the parameter then press this key to confirm A...

Страница 22: ...nate incrustant Check water temperature See Excessive high air suction pressure Check chilling water temperature Refrigerant leakage or insufficient refrigerant volume Test leakage or charge sufficient refrigerant to the system See Excessive low air suction pressure Check ambient temperature around it Discharge the excessive refrigerant Charge sufficient refrigerant to the system Check fan rotatin...

Страница 23: ...pressor Replace damaged assembly Control circuit without power though Check the wring of control system Hi voltage or lo voltage protection Reference to mention in above the parts of air suction and discharge pressure error Replace damaged assembly Find out the error type and carry out the corresponding measure to settle Check the running state Replace a new one if necessary Settle the short circu...

Страница 24: ...on 0 F indicating protection code P is displayed when there is no failure e Unit number display It is used for displaying the address number of the currently selected modular unit with display scope 0 15 and indication point is on at the same time 21 Modular Chiller MUEN H6 E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA Eb EC Ed EF P0 P1 P2 P3 P4 P5 No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23...

Страница 25: ...sor IB Outdoor pipe temperatureT3A Outdoor ambient temperatures T4 Outdoor pipe temperatureT3B 6 7 8 9 10 11 Anti frozen temperature T6 Electronic expansion valv opening FA 12 Last third error or protection Outlet water temperature Tou Last one error or protection Electronic expansion valv opening FB Last second error or protection 13 1 8 5 Care and maintenance Maintenance period It s recommended ...

Страница 26: ... connect the ON OFF port of the main unit s electric control box then connect the ON OFF signal provide by user to the ON OFF port of main unit as follows If the ON OFF port is effective the Net on icon of the wire controller will be flashing First corresponding parallel connect the HEAT COOL port of the main unit s electric control box then connect the ON OFF signal provide by user to the HEAT CO...

Страница 27: ...n 5 Check temperature of chilled water or hot water Inlet Outlet 6 check air temperature of air side heat exchanger Inlet Outlet 7 Check refrigerant suction temperature and superheating temperature Refrigerant suction temperature Superheating temperature 8 Check pressure Discharge pressure Suction pressure 9 Check running current 10 Whether unit has been through refrigerant leakage test 11 Whether...

Страница 28: ...Shutdown Outdoor temperature Compressor Air temperature of air side heat exchanger Temperature of chilled water or hot water Current of cooling water pump or hot water pump Dry bulb Wet bulb Indoor temperature High pressure Low pressure Voltage Current Inlet dry bulb Outlet dry bulb Inlet Outlet Note 25 Modular Chiller MUEN H6 ...

Страница 29: ...in coil model Shell tube type heat exchanger Control of wired controller manual auto startup running state display failure alert etc High or low pressure switch freeze proof device water flow volume controller Overcurrent device power phase sequence device etc Table 9 1 9 APPLICABLE MODELS AND MAIN PARAMETERS Standard heating input kW Heating rated current 36 5 Notes the above data is measured bas...

Страница 30: ...e wiring diagram of auxiliary heater and pump is just for reference please follow the instructions of corresponding auxiliary heater products Please choose such accessory as power wire switch of auxiliary heater according to the actual parameter of products and national Standards 3 3 3 3 3 3 3RZHU 1Њ 3RZHU 1Њ 3RZHU 1Њ 3RZHU 1Њ ...

Страница 31: ... 4 16 11 15 5 6 7 8 9 10 11 12 1 Operation icon 2 Mode area 3 Setting temperature 4 Timing On Off 5 Function Icon 6 On line Unit Qty Indication 7 Reserved 8 Clock 9 Water temp 10 ON OFF Key 11 Right Left Right Key 12 OK key 13 Setting key 14 Add Reduce key 15 Cancel key 16 Reserved key Press for 3sec to cancel timer Press for 3sec to unlock AUXILIARY 1 2 3 4 5 Operation icon Indicate the ON and OF...

Страница 32: ...r 7 seconds then the setting to be effective and the LCD will display the effective timing information as the following display This time the hour of the clock will flash it means the current setting is the hour of Timer 1 Off press the or to adjust press key when finished and then the minute of the clock will flash it means the current setting is the minute of Timing 1 Off press the or to adjust ...

Страница 33: ...tings and return to the main page During setup press the Cancel key does not save the parameters and exit The factory default δ 2 C Simultane ously press Press for 3sec to cancel timer Press for 3sec to unlock AUXILIARY 2 ADDRESS setting function The address of wire controller can be set by pressing this button The address range 0 15 therefore 16 wire controller could be parallel at most Operation...

Страница 34: ...ric control box Please purchase the 3 Core Shield Cable of 0 5mm2 x3 by the customer during installation Black Yellow Grey Communicate with upper unit if there is no upper unit it is no need to be wired E X Y P Q A B P Q E P P Q E Q E 3 core shielding wire 3 core shielding wire E AC22OV Screw Front cover Control panel 3 Wiring figure 1 During installation make sure correctly wiring the 5 wiring te...

Страница 35: ...ole x o b n a i c i r t c e l E 6 8 Diameter Φ8 Φ10 Wall hole and wiring hole Putty Trap Putty Trap Putty Trap Avoid the water enter into the wired remote controller use trap and putty to seal the connectors of wires during wiring installation Fig 5 2 6 Front cover installation Fig 6 2 Fig 6 1 After adjusting the front cover and then buckle the front cover avoid clamping the communication switchin...

Страница 36: ... ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com ...

Отзывы: