HIGH PRESSURE CUTOUT (HPCO) CONTROL
FUNCTION
Stops the ice machine if subjected to excessive high-
side pressure. The HPCO control is normally closed,
and opens on a rise in discharge pressure.
SPECIFICATIONS.
Specifications
Cut-Out
Cut-In
2930 kPa ±29.30 bar ±.69
425 psig ±10
Automatic Reset
Must be below 1978 kPa 19.78 bar (287 psig) to reset.