![Multiplex MB-8-1 Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/multiplex/mb-8-1/mb-8-1_technicians-handbook_1854679135.webp)
135
SYRUP SOLENOID VALVE
Function
Controls supply of CO
2
to product pump.
Specifications
24 VDC
Check Procedure
1. Verify pressure regulator setting is correct.
2. Verify pressure is present at valve inlet.
3. Check for 24 VDC at coil.
•
24 volts is not present - Refer to “Home Position
•
24 volts present - Continue
4. Relieve CO
2
pressure, then disconnect outlet line.
5. Restore CO
2
and test cycle valve:
•
Valve opens - Check for pinched lines and
obstructions.
•
Valve does not open - Replace valve