background image

4 of 9

Document Number: 020009017  May 12, 2022

 

Subject: BIC Tune Up

NOTE: The tubing orientation is 1-9 in a counter clockwise 

manner as shown. 

22. Reposition the dispensing mounting plate to the top of 

the dispensing area and secure with the four (4) outer 

screws.

A.  Reverse actions in Step 16 pulling the tubing 

downwards within the refrigerated cabinet and 

pushing the tubing upwards in the dispensing area 

towards the inside of the tubing chase. 

,

CAUTION

Ice shaver blade is sharp on both edges.  Wear cut resistant gloves 

when handling.

23. Remove the ice assist bar, ice bin lid, ice shelf, paddle 

nut, and shaver wheel. 

24. Using a Phillips head screwdriver remove the four (4) 

screws that secure the ice bin to the condensate bowl.

,

CAUTION

Be careful not to damage push rod when removing the ice bin.    

Push rod should not be bent or have pressure applied to it.

25. Carefully remove the ice bin using caution not to 

damage the micro switch push rod. Use caution not to 

lose any of the three (3) ice bin grommets attached to 

the base of the ice bin bowl. 

26. Wash, rinse and sanitize the condensate bowl.
27. Carefully pour beverage drain cleaner down the ice 

condensate bowl drain opening. 

28. Remove the two (2) screws that secure the shaver blade 

and shims to the ice bin and ice chute cartridge. 

29. Install new blade using old shims.  

NOTE: Shim configuration is important.  Shim alignment 

should be two (2) .056 thick shims and one (1) #7 thin shim.

30. Wash, rinse and sanitize the ice bin.
31. Remove the shaver gasket. You may find the gasket 

adhered to the bottom of the ice bin or the top of the 

dispense area cover.

32. Clean all surfaces where the previous gasket made 

contact.

33. Dry the contact points for the shaver gasket. Adhere 

the new shaver gasket to the top of the dispense area 

cover.

NOTE: Ensure the gasket does not block any of the ice chute 

opening. 

,

CAUTION

Be careful not to damage push rod when reinstalling the ice bin.    

Push rod should be carefully inserted into bottom of ice bin

Содержание BIC MA-8-2

Страница 1: ...IPTION PART NUMBER 1 SWITCH REED RINSE AREA MOD 2160033 1 SWITCH REED RINSE AREA GRAY 2162748 5 FUSE 5A MIXER BOARD 2193015 1 SWITCH SNAP ACTION MINI BLEN HM 2194807 1 BOARD SRB BIC GEN2 2195346 2 CONTROL BLENDER BIC HSM 2195363 1 CONTROL 7 IN UI BIC 000 BIC 01F9 S 1 RELAY 24DC COIL DPDT 2196069 2 FUSE 4A DC HARNESS 2198785 1 PUMP FLOJET NSF NO ASO 3239675 1 MIXER MTR 6MM 120V 50 60 GEN3 SW 323982...

Страница 2: ...rewdriver or pair of needle nose pliers remove the O rings from each blender grate and discard 7 Replace with new O rings over the tip on both grates 8 Wash rinse and sanitize the blender and dispense grates 9 Prepare a five 5 gallon bucket with luke warm tap water no hotter than 105 F 40 5 C and cleaning solution Clean all eight 8 product fittings and connect the cleaning manifold 10 Position the...

Страница 3: ...ea and the pushing up of the tubing inside of the cabinet until the top of the dispensing plate is easily accessible 17 Using a Phillips head screw driver remove the two 2 screws from the metal mounting plate that secures a block of three 3 LMS valves to the dispensing valve mounting plate NOTE The tubing is numbered and will need to be returned to the same position within the dispensing mounting ...

Страница 4: ... using caution not to damage the micro switch push rod Use caution not to lose any of the three 3 ice bin grommets attached to the base of the ice bin bowl 26 Wash rinse and sanitize the condensate bowl 27 Carefully pour beverage drain cleaner down the ice condensate bowl drain opening 28 Remove the two 2 screws that secure the shaver blade and shims to the ice bin and ice chute cartridge 29 Insta...

Страница 5: ... Once the shaver belt is replaced the motor will be returned or very near this same position when tight 38 Locate the four 4 hex head bolts that secure the shaver motor to the motor mounting bracket A Completely remove one of the bolts that secure the Hall Effect sensor mounting bracket to the motor mounting bracket Loosen the remaining three 3 hex head bolts B Swing the Hall Effect mounting brack...

Страница 6: ...and CO2 supply lines and pressure observe for any leaks 54 Power the unit ON using the ON OFF switch located on the upper left side of the unit next to the USB port 55 Connect drain and plug in unit to outlet 56 Verify the water and CO2 pressure regulators are set to 35 psi dynamic and adjust if necessary A The regulators are located on the upper left side of the unit NOTE To achieve a dynamic pre...

Страница 7: ...lect the Configure Slots Icon Select Slot Flavor Select the slot requiring reassignment Select Unassign Flavor and then select the GREEN Check Select the newly Unassigned Slot and select the correct flavor assignment Select the Return Arrow three 3 times to return to the main easyToUCH screen Select product Inventory Icon Select the reassigned flavor and follow the steps for replacing a product ba...

Страница 8: ...ds must be entered to reset the yearly maintenance reminder even though the shafts have NOT been changed Select the MANAGER MENU Select A for the password Select the GREEN check Select the Down Arrow and select SERVICE Select A for the password Select the GREEN check Arrow DOWN and select PLANNED MAINTENANCE Select MIXER MAINTENANCE PERFORMED A 4 0 2 and before Enter SILENCE for password Select th...

Страница 9: ...ge5 ReplacetheCO2andWatersupplylineO rings Step43 44onpage6 Cleanthecondensercoil Step45page6 Cleanthecondensatepan Step46page6 Cleanthecondensatedrainline Step47page6 Pourhotwaterdowndrainopeningsoftheicebin rightblendchamber dispense area andleftblendchamber Step49page6 Workthedrainsbyhandsqueezingoutanybuildup Step51 52onpage6 Connectwater CO2 drain andpowercord Step55page6 Reardrainlineconnect...