37
Programming Options
36
Programming Options
Programming Options
Programming Options 01 and 02 are
automatically programmed by your alarm
SDQHORQÀUVWGLDORXWLQWKH$XVWUDOLDQDQG
New Zealand Versions of the NTD�
1345/1300 or Receiver #
/ Default: Auto detect
*
0
1
#
Contact ID account code used by NTD.
Account Code
/ Default: Auto Detect
*
0
2
#
Contact ID account code used by NTD. Note:
Panels that report multiple account codes may
be changed from the code that was initially
taken from the alarm panel. This option can be
changed during the commissioning procedure
with the Activations Centre.
NTD Alarm Messages
/ Default: 18095099900
*
2
0
X
X
X
X
X
X
X
#
This is the default base Contact ID message, refer
to the Format Template - NTD Alarm Messages
table for individual alarms.
Poll Fail Detection Delay
/ Default: 150
*
2
6
1
5
0
#
This monitors for polling within the programmed
time, this is mapped to the relay’s. Default 150
seconds. See 38 for Relay. See options 39 for
HQDEOLQJ&,'QRWLÀFDWLRQPDS
Power Fault Detection Delay
/ Default: 1
*
2
9
1
#
Delay before reporting power fault (in minutes)
Default 1 minutes. This is mapped to the fault
relays, see 38. See options 39 for enabling CID
QRWLÀFDWLRQ
Zone Enable / Disable
/ Default: 11
ZONE
1
2
*
3
0
1
1
#
To enable zones set to one, to disable set to zero.
Default is all zones are enabled. Zones are all 24
hour zones. These are mapped to fault relays by
option 38.