Explanation of the signals in the assignment plan
13
30283620-02-EN
V3.20151130_rev.2
57
Explanation of the signals in the assignment plan
There is an assignment plan for each implement model. You can obtain the assignment plan
corresponding to your implement from your contact person at Müller-Elektronik.
In the next tables, you will find explanations for the texts that are found on the assignment plan.
Glossary – Input signals
English
Explanation
0VE or GNDE
0V for sensors
12VE
12V for sensors
Calibration button
Sensor that checks if the calibration button is switched.
Work position sensor
Sensor that checks if the implement is in working position
Upper level sensor
Sensor that checks if there is seed in a hopper.
Lower level sensor
Sensor that checks if there is seed in a hopper.
Metering drive speed sensor
Sensor that measures the speed of a metering drive.
Fan speed sensor
Sensor that measures the speed of a fan.
Metering shaft speed sensor
Sensor that measures the speed of a metering shaft.
Vehicle speed sensor
Sensor that measures the speed.
Glossary – Output signals
English
Explanation
0VL or GNDL
0V for actuators
12VL
12V for actuators
Metering drive
Actuator that supplies the metering unit with energy.
Bout marker
Actuator that controls the bout marker.
Pre-emergence marker
Actuator that controls the pre-emergence marker.
Tramline
Actuator that closes the tramline.
Calibration flap
Actuator that opens and closes the calibration flap.